Your browser doesn't support javascript.
loading
Assessment of sick building syndrome using visual analog scales.
Dutheil, Frédéric; Vilmant, Audrey; Boudet, Gil; Mermillod, Martial; Lesage, François-Xavier; Jalenques, Isabelle; Valet, Guillaume; Schmidt, Jeannot; Bouillon-Minois, Jean-Baptiste; Pereira, Bruno.
Afiliação
  • Dutheil F; LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Occupational and Preventive Medicine, WittyFit, Université Clermont Auvergne, CNRS, Clermont-Ferrand, France.
  • Vilmant A; Association Interentreprises en Santé au Travail La Prévention Active, RIOM, France.
  • Boudet G; LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Occupational and Preventive Medicine, Université Clermont Auvergne, CNRS, Clermont-Ferrand, France.
  • Mermillod M; LPNC, Univ. Grenoble Alpes, CNRS, Grenoble, France.
  • Lesage FX; Institut Universitaire de France, Paris, France.
  • Jalenques I; Laboratory Epsylon EA 4556, Dynamic of Human Abilities & Health Behaviors, CHU Montpellier, Occupational Medicine, University of Montpellier, Montpellier, France.
  • Valet G; CHU Clermont-Ferrand, Addictology, Université Clermont Auvergne, NPsy-Sydo, University Hospital of Clermont-Ferrand, Clermont-Ferrand, France.
  • Schmidt J; LaPSCo, Physiological and Psychosocial Stress, Université Clermont Auvergne, CNRS, , Clermont-Ferrand, France.
  • Bouillon-Minois JB; LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Emergency, Université Clermont Auvergne, CNRS, Clermont-Ferrand, France.
  • Pereira B; LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Emergency, Université Clermont Auvergne, CNRS, Clermont-Ferrand, France.
Indoor Air ; 32(3): e13024, 2022 03.
Article em En | MEDLINE | ID: mdl-35347792
BACKGROUND: Despite there is no recommendations for assessing symptoms of sick building syndrome, the use of visual analog scales (VAS) seems attractive and appropriate. We aimed to demonstrate the benefits of using VAS for evaluating subjective symptoms of sick building syndrome. METHOD: We compared an exposed group to a control group with a one-year follow-up. To assess chronology of symptoms, employees were asked to complete four VAS at different times: after vacations (time 1), beginning of the week-beginning of the day (time 2), beginning of the week-end of the day (time 3), and end of the week-end of the day (time 4). Measurements were repeated before and after ventilation work for the exposed group and at the same time in the control group without intervention. Confounding factors were assessed. RESULTS: We included 36 employees (21 in the exposed group and 15 in the control group). Both groups were comparable. Prior to ventilation work, the exposed group had more subjective symptoms than the control group with a chronology of symptoms. After ventilation work, symptoms did not differ between groups, and most symptoms decreased within the exposed group. PRACTICAL IMPLICATION: The use of VAS provided reliable data for assessing sick building syndrome and showed a dose-response relationship between occupational exposure and symptoms.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Poluição do Ar em Ambientes Fechados / Síndrome do Edifício Doente Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Poluição do Ar em Ambientes Fechados / Síndrome do Edifício Doente Idioma: En Ano de publicação: 2022 Tipo de documento: Article