Your browser doesn't support javascript.
loading
Sulfur geochemistry of hydrothermal waters in Yellowstone National Park, Wyoming, USA. III. An anion-exchange resin technique for sampling and preservation of sulfoxyanions in natural waters.
Druschel, Greg K; Schoonen, Martin Aa; Nordstrom, D Kirk; Ball, James W; Xu, Yong; Cohn, Corey A.
Afiliação
  • Druschel GK; Dept. of Geosciences, State University of New York at Stony Brook, Stony Brook, NY 11794.
  • Schoonen MA; College of Marine Studies, University of Delaware 700 Pilottown Road, Lewes, DE 19958.
  • Nordstrom DK; Dept. of Geosciences, State University of New York at Stony Brook, Stony Brook, NY 11794.
  • Ball JW; U.S. Geological Survey, 3215 Marine Street, Boulder, CO 80303.
  • Xu Y; U.S. Geological Survey, 3215 Marine Street, Boulder, CO 80303.
  • Cohn CA; Dept. of Geosciences, SUNY at Stony Brook, Stony Brook, NY 11794.
Geochem Trans ; 4: 12, 2003.
Article em En | MEDLINE | ID: mdl-35412784
ABSTRACT
A sampling protocol for the retention, extraction, and analysis of sulfoxyanions in hydrothermal waters has been developed in the laboratory and tested at Yellowstone National Park and Green Lake, NY. Initial laboratory testing of the anion-exchange resin Bio-Rad™ AG1-X8 indicated that the resin was well suited for the sampling, preservation, and extraction of sulfate and thiosulfate. Synthetic solutions containing sulfate and thiosulfate were passed through AG1-X8 resin columns and eluted with 1 and 3 M KCl, respectively. Recovery ranged from 89 to 100%. Comparison of results for water samples collected from five pools in Yellowstone National Park between on-site 1C analysis (U.S. Geological Survey mobile lab) and IC analysis of resin-stored sample at SUNY-Stony Brook indicates 96 to 100% agreement for three pools (Cinder, Cistern, and an unnamed pool near Cistern) and 76 and 63% agreement for two pools (Sulfur Dust and Frying Pan). Attempts to extract polythionates from the AG1-X8 resin were made using HCl solutions, but were unsuccessful. Bio-Rad™ AG2-X8, an anion-exchange resin with weaker binding sites than the AG1-X8 resin, is better suited for polythionate extraction. Sulfate and thiosulfate extraction with this resin has been accomplished with KCl solutions of 0.1 and 0.5 M, respectively. Trithionate and tetrathionate can be extracted with 4 M KCl. Higher polythionates can be extracted with 9 M hydrochloric acid. Polythionate concentrations can then be determined directly using ion chromatographic methods, and laboratory results indicate recovery of up to 90% for synthetic polythionate solutions using AG2-X8 resin columns.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2003 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2003 Tipo de documento: Article