Your browser doesn't support javascript.
loading
Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation.
Malebranche, Daniel; Hoffner, Maximilian K M; Huber, Adrian T; Cicovic, Aleksandar; Spano, Giancarlo; Bernhard, Benedikt; Bartkowiak, Joanna; Okuno, Taishi; Lanz, Jonas; Räber, Lorenz; Praz, Fabien; Stortecky, Stefan; Windecker, Stephan; Pilgrim, Thomas; Gräni, Christoph.
Afiliação
  • Malebranche D; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Hoffner MKM; Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University of Bern, Bern, Switzerland.
  • Huber AT; Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University of Bern, Bern, Switzerland.
  • Cicovic A; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Spano G; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Bernhard B; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Bartkowiak J; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Okuno T; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Lanz J; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Räber L; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Praz F; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Stortecky S; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Windecker S; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Pilgrim T; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland.
  • Gräni C; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland. christoph.graeni@insel.ch.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Article em En | MEDLINE | ID: mdl-35436856
ABSTRACT

BACKGROUND:

Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients.

METHODS:

In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis).

RESULTS:

100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone.

CONCLUSION:

In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Doença da Artéria Coronariana / Estenose Coronária / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Doença da Artéria Coronariana / Estenose Coronária / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2022 Tipo de documento: Article