Your browser doesn't support javascript.
loading
Induced Radionuclides and Their Activity Concentration in Gel Dosimeters Irradiated by Carbon Ion Beam.
Toyohara, Masumitsu; Minohara, Shinichi; Kusano, Yohsuke; Gotoh, Hiroaki; Tanaka, Yoichiro; Yuhara, Masaru; Yamashita, Yu; Shimono, Yoshiaki.
Afiliação
  • Toyohara M; Research Initiative and Promotion Organization, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501, Japan.
  • Minohara S; Toshiba Energy Systems & Solutions Corporation, Kawasaki 212-8585, Japan.
  • Kusano Y; Kanagawa Cancer Center, Yokohama 241-8585, Japan.
  • Gotoh H; Kanagawa Cancer Center, Yokohama 241-8585, Japan.
  • Tanaka Y; Department of Chemistry and Life Science, Yokohama National University, Yokohama 240-8501, Japan.
  • Yuhara M; Research Initiative and Promotion Organization, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501, Japan.
  • Yamashita Y; Toshiba Energy Systems & Solutions Corporation, Kawasaki 212-8585, Japan.
  • Shimono Y; Toshiba Energy Systems & Solutions Corporation, Kawasaki 212-8585, Japan.
Gels ; 8(4)2022 Mar 23.
Article em En | MEDLINE | ID: mdl-35448104
ABSTRACT
Radioactivity was measured in a micellar gel dosimeter, a polymer gel dosimeter, and water was irradiated by carbon ion beams at various beam energy conditions. Monte Carlo simulation was also performed to estimate the radioactivity. Short-lived positron-emitting nuclides were observed immediately after irradiation, but they decayed rapidly into the background. At 24 h post-irradiation, the dominant measured radioactivity was of 7Be. The simulation also showed minor activity of 24Na and 3H; however, they were not experimentally observed. The measured radioactivity was independent of the type of gel dosimeter under all irradiation conditions, suggesting that the radioactivity was induced by the interaction of carbon ions with water (the main component of the gel dosimeters). The ratio between the simulated and measured radioactivity was within 0.9-1.5. The activity concentration of 7Be was found to be less than 1/10 of the value derived using the exemption concept proposed by the International Atomic Energy Agency. This result should be applicable to irradiated gel dosimeters containing mainly water and 0-4 wt.% C and 0-1.7 wt.% N.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article