Your browser doesn't support javascript.
loading
Stretched reconstruction based on 2D freehand ultrasound for peripheral artery imaging.
Leblanc, Thomas; Lalys, Florent; Tollenaere, Quentin; Kaladji, Adrien; Lucas, Antoine; Simon, Antoine.
Afiliação
  • Leblanc T; Therenva, 35000, Rennes, France. thomas.leblanc@therenva.com.
  • Lalys F; Univ Rennes, CHU Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France. thomas.leblanc@therenva.com.
  • Tollenaere Q; Therenva, 35000, Rennes, France.
  • Kaladji A; Vascular Medicine Unit, CHU Rennes, 35033, Rennes, France.
  • Lucas A; Univ Rennes, CHU Rennes, CLCC Eugène Marquis, Inserm, LTSI - UMR 1099, F-35000, Rennes, France.
  • Simon A; Department of Cardiothoracic and Vascular Surgery, CHU Rennes, 35033, Rennes, France.
Int J Comput Assist Radiol Surg ; 17(7): 1281-1288, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35486303
PURPOSE: Endovascular revascularization is becoming the established first-line treatment of peripheral artery disease (PAD). Ultrasound (US) imaging is used pre-operatively to make the first diagnosis and is often followed by a CT angiography (CTA). US provides a non-invasive and non-ionizing method for the visualization of arteries and lesion(s). This paper proposes to generate a 3D stretched reconstruction of the femoral artery from a sequence of 2D US B-mode frames. METHODS: The proposed method is solely image-based. A Mask-RCNN is used to segment the femoral artery on the 2D US frames. In-plane registration is achieved by aligning the artery segmentation masks. Subsequently, a convolutional neural network (CNN) predicts the out-of-plane translation. After processing all input frames and re-sampling the volume according to the vessel's centerline, the whole femoral artery can be visualized on a single slice of the resulting stretched view. RESULTS: 111 tracked US sequences of the left or right femoral arteries have been acquired on 18 healthy volunteers. fivefold cross-validation was used to validate our method and achieve an absolute mean error of 0.28 ± 0.28 mm and a median drift error of 8.98%. CONCLUSION: This study demonstrates the feasibility of freehand US stretched reconstruction following a deep learning strategy for imaging the femoral artery. Stretched views are generated and can give rich diagnosis information in the pre-operative planning of PAD procedures. This visualization could replace traditional 3D imaging in the pre-operative planning process, and during the pre-operative diagnosis phase, to identify, locate, and size stenosis/thrombosis lesions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento Tridimensional / Doença Arterial Periférica Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento Tridimensional / Doença Arterial Periférica Idioma: En Ano de publicação: 2022 Tipo de documento: Article