Your browser doesn't support javascript.
loading
Simultaneous determination of eight ß-adrenergic agonists in human urine by an isotope dilution-online clean-up system coupled with liquid chromatography-tandem mass spectrometry.
Wang, Chien-Jen; Liu, Huei-Ju; Chou, Tzu-Chieh; Lin, Ching-Chun; Pan, Wen-Harn; Chen, Pau-Chung; Hsu, Jing-Fang.
Afiliação
  • Wang CJ; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, 35053, Taiwan.
  • Liu HJ; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, 35053, Taiwan.
  • Chou TC; Department of Public Health, College of Public Health, China Medical University, Taichung, 40678, Taiwan.
  • Lin CC; Institute of Environmental and Occupational Health Sciences, National Taiwan University College of Public Health, Taipei, Taiwan.
  • Pan WH; Institute of Biomedical Sciences, Academia Sinica, Taipei, Taiwan; Institute of Population Health Sciences, National Health Research Institutes, Miaoli, 35053, Taiwan.
  • Chen PC; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, 35053, Taiwan; Institute of Environmental and Occupational Health Sciences, National Taiwan University College of Public Health, Taipei, Taiwan; Department of Public Health, National Taiwan University C
  • Hsu JF; National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, 35053, Taiwan. Electronic address: JFH428@nhri.edu.tw.
Chemosphere ; 301: 134778, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35504472
ABSTRACT
ß-Adrenergic agonist compounds are medicines that open up the lung's medium and large airways. ß-Adrenergic agonist compounds have been illegally or legally used to increase lean muscle mass in meat animals, bodybuilding, weight-loss programs, and athletes. Developing a rapid analytical approach for determining ß-adrenergic agonist compounds in biological samples is crucial for individual exposure assessment. This study established an analytical method for simultaneously measuring eight ß-adrenergic agonist compounds in human urine, including clenbuterol, terbutaline, salbutamol, ractopamine, zilpaterol, cimaterol, tulobuterol, and fenoterol. Two hundred microliters of a urine sample were added to eight deuterium-labeled internal standard mixtures and glucuronidase/arylsulfatase for enzymatic hydrolysis, and were then analyzed using an online clean-up system coupled with a liquid chromatography-tandem mass spectrometry system (LC-MS/MS). The limit of quantification ranged from 0.03 to 0.12 ng/mL urine for the eight ß-adrenergic agonist compounds. The relative standard deviations (RSD) of the within-run and between-run precisions were less than 10%, and the relative accuracy errors were less than 17% in the three-level spiked artificial urine samples. Two hundred eighty human urine samples collected from the general population in Taiwan were assessed to demonstrate the capability and feasibility of this method. The detection frequencies were 33% for clenbuterol, 5% for ractopamine, and less than 5% for the others. We concluded that the isotope dilution-online clean-up system coupled with LC-MS/MS method is a valuable analytical method for investigating urinary ß-adrenergic agonist compounds in humans and is valuable for human biomonitoring studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Clembuterol Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Clembuterol Idioma: En Ano de publicação: 2022 Tipo de documento: Article