Your browser doesn't support javascript.
loading
The influence of methodology on the comparison of cytotoxicity of total-etch and self-etch adhesive systems.
Caldas, Isleine Portal; da Silva, Eduardo Moreira; Lourenço, Emanuelle Stellet; Martins do Nascimento, Jean Carlos; Leite, Paulo Emilio Correa; Leão, Moira Pedroso; Alves, Gutemberg; Scelza, Miriam Zaccaro.
Afiliação
  • Caldas IP; Geriatric Dentistry Department, School of Dentistry, Fluminense Federal University (UFF), Niterói, RJ, Brazil.
  • da Silva EM; Analytical Laboratory of Restorative Biomaterials - LABiom-R, School of Dentistry, Fluminense Federal University, Niterói, RJ, Brazil.
  • Lourenço ES; Post-graduation Program in Dentistry of Fluminense Federal University (UFF), Niteroi, RJ, Brazil.
  • Martins do Nascimento JC; Laboratory of Experimental Culture Cell (LECCel), School of Dentistry, Fluminense Federal University (UFF), Niteroi, RJ, Brazil.
  • Leite PEC; Clinical Research Unit of the Antonio Pedro Hospital, Fluminense Federal University, Niteroi, RJ, Brazil.
  • Leão MP; Curityba Biotech Cell Processing Center, Curitiba, PR, Brazil.
  • Alves G; Clinical Research Unit of the Antonio Pedro Hospital, Fluminense Federal University, Niteroi, RJ, Brazil; Cell and Molecular Biology Department, Institute of Biology, Fluminense Federal University, Niteroi, Brazil.
  • Scelza MZ; Laboratory of Experimental Culture Cell (LECCel), School of Dentistry, Fluminense Federal University (UFF), Niteroi, RJ, Brazil; Endodontics Department, School of Dentistry, Fluminense Federal University (UFF), Niteroi, RJ, Brazil. Electronic address: scelza@terra.com.br.
J Dent ; 122: 104158, 2022 07.
Article em En | MEDLINE | ID: mdl-35550400
OBJECTIVES: The present study aimed to compare the in vitro cytocompatibility of two etch-and-rinse (Adper Scothbond, Optibond) and two self-etch (Clearfill SE Bond and Single Bond Universal) dental adhesives through a dentin-barrier model with human pulp fibroblasts. METHODS: Human fibroblasts were placed on a plastic device containing 500µm human dentin discs treated with each adhesive or without treatment (control). Other groups were directly exposed to media conditioned with adhesive samples according to ISO 10993-5:2009. After 24h exposure, cell viability was assessed by XTT, and released inflammatory mediators were detected with a multiparametric immunoassay. RESULTS: The standardized test without barrier indicated both etch-and-rinse adhesives and self-etch as cytotoxic, promoting viabilities under 70% of the control group (p<0.05). The dentin-barrier model identified increased cell viability for self-etch adhesives, with Clearfill SE Bond identified as non-cytotoxic. The immunoassay evidenced high rates of cytokines by cells exposed to the conditioned media of Adper Scotchbond, Optibond S, and Single Bond Universal. CONCLUSIONS: The use of a dentin-barrier in vitro model detected a better biocompatibility for self-etching adhesives and, in the case of Clearfill SE Bond, with a reversion from cytotoxic to biocompatible when compared to the indirect standardized test. CLINICAL SIGNIFICANCE: The use of a dentin-barrier in vitro model was able to detect a better biocompatibility for self-etching adhesives when compared to the indirect standardized test and presents itself as a predictive in vitro method for assessing the cytotoxicity of dental restorative materials that may simulate the clinical condition more accurately.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Adesivos Dentinários Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Adesivos Dentinários Idioma: En Ano de publicação: 2022 Tipo de documento: Article