Your browser doesn't support javascript.
loading
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds.
Dohr, Dana; Wulf, Katharina; Grabow, Niels; Mlynski, Robert; Schraven, Sebastian P.
Afiliação
  • Dohr D; Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, 18057 Rostock, Germany.
  • Wulf K; Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany.
  • Grabow N; Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany.
  • Mlynski R; Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, 18057 Rostock, Germany.
  • Schraven SP; Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner", Rostock University Medical Center, 18057 Rostock, Germany.
Materials (Basel) ; 15(9)2022 Apr 22.
Article em En | MEDLINE | ID: mdl-35591381
ABSTRACT
To prevent endocochlear insertion trauma, the development of drug delivery coatings in the field of CI electrodes has become an increasing focus of research. However, so far, the effect of a polymer coating of PLLA on the mechanical properties, such as the insertion pressure and friction of an electrode array, has not been investigated. In this study, the insertion pressure of a PLLA-coated, 31.5-mm long standard electrode array was examined during placement in a linear cochlear model. Additionally, the friction coefficients between a PLLA-coated electrode array and a tissue simulating the endocochlear lining were acquired. All data were obtained at different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s) and compared with those of an uncoated electrode array. It was shown that both the maximum insertion pressure generated in the linear model and the friction coefficient of the PLLA-coated electrode did not depend on the insertion speed. At higher insertion speeds above 1.0 mm/s, the insertion pressure (1.268 ± 0.032 mmHg) and the friction coefficient (0.40 ± 0.15) of the coated electrode array were similar to those of an uncoated array (1.252 ± 0.034 mmHg and 0.36 ± 0.15). The present study reveals that a PLLA coating on cochlear electrode arrays has a negligible effect on the electrode array insertion pressure and the friction when higher insertion speeds are used compared with an uncoated electrode array. Therefore, PLLA is a suitable material to be used as a coating for CI electrode arrays and can be considered for a potential drug delivery system.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article