Your browser doesn't support javascript.
loading
Quantification of prefusion conformation for HIV vaccine using size-exclusion chromatography.
Gollapudi, Deepika; Shadrick, William; Yang, Yanhong; Gowetski, Daniel B; Gall, Jason; Paula Lei, Q.
Afiliação
  • Gollapudi D; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA.
  • Shadrick W; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA.
  • Yang Y; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA.
  • Gowetski DB; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA.
  • Gall J; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA.
  • Paula Lei Q; Vaccine Production Program, VRC, NIAID, NIH, 9 W. Watkins Mill Road, Gaithersburg, MD, USA. Electronic address: paula.lei@nih.gov.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1201-1202: 123296, 2022 Jun 30.
Article em En | MEDLINE | ID: mdl-35598458
A closed prefusion conformation or an open (non-prefusion) conformational state of a protein vaccine candidate molecule can determine if it effectively elucidates a desired immunity. A quick and reliable method to monitor conformational state is important during vaccine development. In addition to our existing immunoassays, we have developed a unique physicochemical approach using size-exclusion chromatography to assess binding between antibody and the structurally desired antigen protein. Through the bound monoclonal antibody protein vaccine peak shift in the size-exclusion chromatography profile, this method determines the percent closed (prefusion) conformation present in a sample. Since only the closed prefusion conformation binds to the specific antibody, the population of the closed versus the open conformation of the vaccine molecule can be monitored without the need for a reference calibrator. This new method can be applied broadly to vaccine development, as well as for antibody selection during antibody drug discovery. The mAb CAP256V2LS (250 µg/mL) specific to prefusion conformation was mixed with HIV trimer (250 µg/mL) at 2:1 volume ratio, incubated at 37 °C for 30 mins and injected onto HPLC column. The percent of non-prefusion conformation was calculated based on ratio of peak area of unbound trimer and total area of control trimer sample (without mAb).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: HIV-1 / Vacinas contra a AIDS Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: HIV-1 / Vacinas contra a AIDS Idioma: En Ano de publicação: 2022 Tipo de documento: Article