Your browser doesn't support javascript.
loading
Glycerol as a new mobile phase modifier for green liquid chromatographic determination of ascorbic acid and glutathione in pharmaceutical tablets.
Habib, Ahmed; Mabrouk, Mokhtar M; Fekry, Marwa; Mansour, Fotouh R.
Afiliação
  • Habib A; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt; Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt. Electronic address: ahmed.habib1@pharm.tanta.edu.eg.
  • Mabrouk MM; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt; Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt. Electronic address: mokhtaribrahim50@yahoo.com.
  • Fekry M; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt. Electronic address: PG_123977@pharm.Tanta.edu.eg.
  • Mansour FR; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt; Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt. Electronic address: fotouhrashed@pharm.tanta.edu.eg.
J Pharm Biomed Anal ; 219: 114870, 2022 Sep 20.
Article em En | MEDLINE | ID: mdl-35715373
ABSTRACT
Fixed dose combinations of glutathione and ascorbic acid are marketed due to the synergetic effect of glutathione, which regenerates ascorbic acid, potentiates its action and prolongs its antioxidant potential. In this work, glycerol was introduced for the first time as a green mobile phase modifier for liquid chromatographic determination of glutathione and ascorbic acid in pharmaceutical tablets. The viscosity barrier was overcome by using water as a co-fluidifying solvents and by controlling the column temperature. Compared with methanol and acetonitrile, glycerol could result in better peak shapes and superior system suitability. To explore the retention process, free energy and enthalpy-entropy compensation were calculated for both glutathione and ascorbic acid. The chromatographic conditions were optimized using factorial design with the aid of Minitab 17® Software. The method was successfully validated according to the guidelines of the International Conference on Harmonization Q2 (R1) and was found linear in the range of 1 µg/mL to 300300 µg/mL for both drugs. The method was evaluated in terms of its greenness and then compared to the reported method. Glycerol has several advantages over commonly employed mobile phase modifiers, such as the high safety, the low UV cut-off point, low flammability, low volatility, the green features, and the biodegradability. This work paves the way for more applications of glycerol in green liquid chromatography.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Glicerol Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Glicerol Idioma: En Ano de publicação: 2022 Tipo de documento: Article