Your browser doesn't support javascript.
loading
Impact of different complete coverage onlay preparation designs and the intraoral scanner on the accuracy of digital scans.
de Andrade, Guilherme Schmitt; Luz, Julio Nogueira; Tribst, João Paulo Mendes; Chun, Eliseo Pablo; Bressane, Adriano; Borges, Alexandre Luiz Souto; Saavedra, Guilherme de Siqueira Ferreira Anzaloni.
Afiliação
  • de Andrade GS; Assistant Professor, Center of Biological and Health Sciences, School of Dentistry, Western Paraná State University (Unioeste), Cascavel, PR, Brazil. Electronic address: guisdandrade@hotmail.com.
  • Luz JN; Assistant Professor, Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University - UNESP, São José dos Campos, SP, Brazil; Adjunct Professor, Department of Dentistry, School of Dentistry, University of Guarulhos (UNG), Guarulhos, SP, Brazil.
  • Tribst JPM; Assistant Professor, Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Chun EP; Faculty, School of Dentistry, Espiritu Santo University, Samborondon, Ecuador.
  • Bressane A; Associate Professor, Applied Oral Health Sciences Post-Graduate Program, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil.
  • Borges ALS; Associate Professor, Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil.
  • Saavedra GSFA; Associate Professor, Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil.
J Prosthet Dent ; 2022 Jun 15.
Article em En | MEDLINE | ID: mdl-35717209
ABSTRACT
STATEMENT OF

PROBLEM:

The trueness and precision of intraoral scanners (IOSs) and the effect of intracoronal restorations have been reported. However, studies addressing the accuracy of IOSs in reproducing different complete coverage onlay preparation designs are lacking.

PURPOSE:

The purpose of this in vitro study was to evaluate the influence of complete coverage onlay preparation design and intraoral scanning devices on the accuracy of digital scans in terms of trueness and precision. MATERIAL AND

METHODS:

Three preparation designs on the mandibular first molar were considered a traditional preparation design with isthmus reduction (IST), a traditional preparation design without isthmus reduction (wIST), and simplified nonretentive preparation (nRET). Digital scans of epoxy resin mandibular arch reference models of the preparations (containing second premolar, first molar, and second molar) were obtained by using 3 IOSs (iTero Element 2 [ELE], Trios 3 [TRI], and Primescan [PRI]) (n=10). Trueness (µm) and precision (µm) were analyzed by superimposing the digital scan on the digital reference models obtained with a high-accuracy industrial scanner (ATOS Core 80) in a tridimensional metrology software program. Accuracy was quantified by the absolute deviation (µm). Local and overall mean positive and negative deviations for trueness were also obtained. Data were analyzed by using the Kruskal-Wallis and Dunn tests with a statistical software program (α=.05).

RESULTS:

The nonretentive preparation groups obtained higher trueness (3.8 µm) and precision (2.7 µm) than the IST and wIST groups (trueness=7.5 to 6.3 µm, precision=5.5 to 4.6 µm). Trueness values were lower with ELE×IST (16 µm), followed by ELE×wIST (13 µm), and PRI×IST (7.8 µm). In general, no difference was found between PRI and TRI scanners (6.3 to 5.9 µm), with lower performance for ELE (13 µm). Positive deviations were higher on the proximal box of the IST and wIST preparation and on the occlusal box of the IST group. Negative deviation was higher on the ELE×IST occlusal box.

CONCLUSIONS:

Different intraoral scanners and preparation designs influenced the accuracy of digital scans. A more complex preparation such as IST and wIST showed higher deviation. The iTero Element 2 scanner exhibited higher deviation for both trueness and precision.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article