Your browser doesn't support javascript.
loading
Development of a new SPE UPLC-MS/MS method for extraction and quantitation of toluene diamine on gloves following toluene diisocyanate exposure.
Daoud, Asma; Cloutier, Pierre-Luc; Gagné, Sébastien; Breau, Livain; Lesage, Jacques.
Afiliação
  • Daoud A; Chemistry Department, Université du Québec à Montréal, Montreal, Canada.
  • Cloutier PL; Laboratory Division, Institut de recherche Robert-Sauvé en santé et en sécurité du travail, Montréal, Canada.
  • Gagné S; Laboratory Division, Institut de recherche Robert-Sauvé en santé et en sécurité du travail, Montréal, Canada.
  • Breau L; Laboratory Division, Institut de recherche Robert-Sauvé en santé et en sécurité du travail, Montréal, Canada.
  • Lesage J; Chemistry Department, Université du Québec à Montréal, Montreal, Canada.
Rapid Commun Mass Spectrom ; 36(16): e9340, 2022 Aug 30.
Article em En | MEDLINE | ID: mdl-35729786
ABSTRACT
RATIONALE Toluene diisocyanate (TDI) is a highly reactive isocyanate commonly used as a mixture of 2,4- and 2,6- isomers in the production of flexible foams. Exposure to TDI occurs primarily through vapour inhalation in workplaces where TDI is produced or used, but dermal exposure is also possible during some tasks. To ensure workplace safety, accurate monitoring of TDI and toluene diamine (TDA) levels is required. Methods of quantifying field effectiveness of gloves in preventing dermal exposure have not been established. Therefore, there is a need to develop a new practical method for assessing glove effectiveness for TDI/TDA.

METHOD:

A new offline SPE UPLC-MS/MS method for the quantitation of TDA isomers from TDI-exposed gloves was developed. Gloves were dipped in a solution of 1% acetic acid leading to a full conversion to TDA. TDA-free amine compounds were derivatized with acetic anhydride to increase chromatographic retention and signal intensity.

RESULTS:

2,4-Diaminotoluene-α, α, α-d3 (2,4-d3 -TDA) was selected as a surrogate standard to minimise the variability in sample preparation and instrumental sensitivity. The choice of UPLC-MS/MS operated in multiple reaction monitoring (MRM) mode allowed to reach much lower limits of detection (LOD). The LOD of the method was 6.86 and 2.83 ng/mL (0.03 and 0.01 µg) for 2,6-TDA and 2,4-TDA, respectively. The limit of quantitation (LOQ) was 22.85 and 9.42 ng/mL (0.11 and 0.05 µg) for 2,6-TDA and 2,4-TDA, respectively.

CONCLUSION:

A new UPLC-MS/MS analytical method has been developed to determine field effectiveness of gloves for preventing dermal exposure to TDI/TDA. The new technique overcomes some limitations for measuring putative dermal exposure to isocyanates and may be useful in exposure monitoring and future research on isocyanate health risks.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tolueno 2,4-Di-Isocianato Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tolueno 2,4-Di-Isocianato Idioma: En Ano de publicação: 2022 Tipo de documento: Article