Your browser doesn't support javascript.
loading
Rapid SARS-CoV-2 Virus Enrichment and RNA Extraction for Efficient Diagnostic Screening of Pooled Nasopharyngeal or Saliva Samples for Dilutions Up to 1:100.
Marshall, Jamila S; Turiello, Rachelle; Cunha, Larissa L; Frazier, Ella V; Hickey, Jeff; Chapman, Jeff; Poulter, Melinda D; Fehling, Heather L; Landers, James P.
Afiliação
  • Marshall JS; Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA.
  • Turiello R; Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA.
  • Cunha LL; Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA.
  • Frazier EV; Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA.
  • Hickey J; MicroGEM International PLC, Charlottesville, VA 22903, USA.
  • Chapman J; MicroGEM International PLC, Charlottesville, VA 22903, USA.
  • Poulter MD; Department of Pathology, University of Virginia, Charlottesville, VA 22903, USA.
  • Fehling HL; Clinical Reference Laboratory, Lenexa, KS 66215, USA.
  • Landers JP; Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA.
Diagnostics (Basel) ; 12(6)2022 Jun 06.
Article em En | MEDLINE | ID: mdl-35741208
ABSTRACT
As COVID-19 transmission control measures are gradually being lifted, a sensitive and rapid diagnostic method for large-scale screening could prove essential for monitoring population infection rates. However, many rapid workflows for SARS-CoV-2 detection and diagnosis are not amenable to the analysis of large-volume samples. Previously, our group demonstrated a technique for SARS-CoV-2 nanoparticle-facilitated enrichment and enzymatic lysis from clinical samples in under 10 min. Here, this sample preparation strategy was applied to pooled samples originating from nasopharyngeal (NP) swabs eluted in viral transport medium (VTM) and saliva samples diluted up to 1100. This preparation method was coupled with conventional RT-PCR on gold-standard instrumentation for proof-of-concept. Additionally, real-time PCR analysis was conducted using an in-house, ultra-rapid real-time microfluidic instrument paired with an experimentally optimized rapid protocol. Following pooling and extraction from clinical samples, average cycle threshold (CT) values from resultant eluates generally increased as the pooling dilution factor increased; further, results from a double-blind study demonstrated 100% concordance with clinical values. In addition, preliminary data obtained from amplification of eluates prepared by this technique and analyzed using our portable, ultra-rapid real-time microfluidic PCR amplification instrument showed progress toward a streamlined method for rapid SARS-CoV-2 analysis from pooled samples.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article