Your browser doesn't support javascript.
loading
Disposable Electrochemical Aptasensor Based on Graphene Oxide-DNA Complex as Signal Amplifier towards Ultrasensitive Detection of Ochratoxin A.
Hu, Yang; Xie, Hanyin; Hu, Jiaying; Yang, Danting.
Afiliação
  • Hu Y; Department of Preventative Medicine, Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China.
  • Xie H; Department of Preventative Medicine, Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China.
  • Hu J; Department of Preventative Medicine, Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China.
  • Yang D; Department of Preventative Medicine, Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China.
Micromachines (Basel) ; 13(6)2022 May 26.
Article em En | MEDLINE | ID: mdl-35744448
ABSTRACT
Signal amplification is crucial in developing a reliable disposable screen-printed carbon electrodes (SPCEs)-based biosensor for analyte detection with a narrow detection window. This work demonstrated a novel label-free electrochemical aptasensor based on SPCEs for the ultrasensitive detection of ochratoxin A (OTA). The graphene oxide-DNA (GO-DNA) complex as a signal amplifier with easy preparation was investigated for the first time. The proposed aptasensor based on the SPCEs/GO/cDNA-aptamer/3D-rGO-AuNPs structure was formed through the hybridization of aptamer-linked 3D-rGO/AuNPs and its complementary DNA-linked GO (GO-cDNA). The presence of OTA was discerned by its specific aptamer forming a curled OTA-aptamer complex and releasing the GO-cDNA from the surface of SPCEs. The resulting OTA-aptamer complex hindered interfacial electron transfer on the sensing surface, leading to the decreased peak current. The GO-cDNA further amplified the peak current change. This electrochemical aptasensor showed a low limit of detection of 5 fg/mL as well as good reproducibility with the relative standard deviation (RSD) of 4.38%. Moreover, the detection result of OTA in the rice and oat samples was comparable with that of the enzyme-linked immunosorbent assay (ELISA) kit. In general, the OTA aptasensor used in this work with convenient preparation, low-cost, good selectivity, high sensitivity and acceptable reproducibility can be proposed as a reliable point-of-care (POC) technique for OTA determination.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article