A case of successful desensitization using therapeutic plasma exchange in high-risk HLA incompatible kidney transplantation.
Transpl Immunol
; 74: 101656, 2022 10.
Article
em En
| MEDLINE
| ID: mdl-35787931
Advances in immune suppression therapies and desensitization have made possible kidney transplantation regardless of HLA incompatibility. Single antigen bead assay (SAB) is a semi-quantitative estimation of the amount of human leukocyte antigen (HLA) antibodies present in the recipient plasma, and mean fluorescence intensity (MFI) generated gives this rough estimation of the antibodies present in the recipient. Here we present a case of successful kidney transplantation in a patient who expressed DSA with high MFI. A 33-yr-old male, diagnosed with chronic kidney disease (CKD) on regular maintenance hemodialysis, opted for second kidney transplant with his sibling as prospective donor and was referred to the department of Transplant Immunology for histocompatibility testing. Patient had HLA incompatibility with multiple DSA identified by SAB. Patient undergone 20 sessions of plasma exchange till discharge and finally till 6 months graft was functioning well. The authors thus conclude that the option of a high-risk HLA incompatible kidney transplant can be offered to recipients with high MFI DSA, who wish to undergo transplantation for end stage renal disease.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Transplante de Rim
Idioma:
En
Ano de publicação:
2022
Tipo de documento:
Article