Your browser doesn't support javascript.
loading
Drilling the cement mantle in well-fixed periprosthetic femur fractures is not associated with arthroplasty-related complications.
Van Rysselberghe, Noelle L; DeBaun, Malcolm R; Sanchez, Mark; Wadhwa, Harsh; Pfaff, Kayla E; Bellino, Michael J; Gardner, Michael J; Bishop, Julius A.
Afiliação
  • Van Rysselberghe NL; Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA. nvanry@stanford.edu.
  • DeBaun MR; Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA.
  • Sanchez M; Stanford University School of Medicine, Stanford, CA, USA.
  • Wadhwa H; Stanford University School of Medicine, Stanford, CA, USA.
  • Pfaff KE; Case Western Reserve, University School of Medicine, Cleveland, OH, USA.
  • Bellino MJ; Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA.
  • Gardner MJ; Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA.
  • Bishop JA; Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA.
Eur J Orthop Surg Traumatol ; 33(5): 1629-1633, 2023 Jul.
Article em En | MEDLINE | ID: mdl-35788424
ABSTRACT

OBJECTIVE:

To determine if screw fixation across a cement mantle is safe and effective during plate fixation of well-fixed periprosthetic femur fractures.

DESIGN:

Retrospective cohort study.

SETTING:

Academic Level I Trauma Center. PATIENTS Twenty-eight patients with AO/OTA 32A[B1] or 32A[C] periprosthetic femur fractures treated with open reduction and internal plate and screw fixation after cemented or uncemented hip arthroplasty. INTERVENTION Screw placement into the cement mantle during internal fixation. OUTCOME MEASUREMENTS Primary outcome was revision arthroplasty for aseptic loosening. Secondary outcomes included radiographic evidence of aseptic loosening, infection, nonunion, implant failure, and overall reoperation rate.

RESULTS:

There were 28 patients who met inclusion criteria. A total of 9 patients had screws placed in the cement mantle while the remaining 19 patients had screws placed around an uncemented stem. At a mean of 3.7-year follow-up, there were no cases of revision arthroplasty or aseptic loosening in either group. There were no significant differences in rates of infection, nonunion, implant failure, or reoperation rate between patients who had screw placement into a cement mantle vs around an uncemented stem.

CONCLUSION:

Drilling into the cement mantle during fixation of a periprosthetic femur fracture around a well-fixed cemented hip stem appears safe and effective. When possible, surgeons can consider bicortical screws around a cemented stem, given the biomechanical advantages over unicortical screw or cerclage fixation. Larger prospective trials confirming the safety of this technique are warranted prior to routine implementation. LEVEL OF EVIDENCE III.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas Periprotéticas / Fraturas do Fêmur / Prótese de Quadril Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas Periprotéticas / Fraturas do Fêmur / Prótese de Quadril Idioma: En Ano de publicação: 2023 Tipo de documento: Article