Your browser doesn't support javascript.
loading
GO/iron series systems enhancing the pH shock resistance of anaerobic systems for sulfate-containing organic wastewater treatment.
Wang, Longyu; Li, Haoyang; Wang, Xiao; Liu, Xiaofeng; Ma, Weiqing; Zhou, Guangji; Liang, Qiaochu; Lan, Huixia.
Afiliação
  • Wang L; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Li H; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Wang X; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Liu X; Shandong Linglong Tire Co., Ltd Yantai 265406 China.
  • Ma W; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Zhou G; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Liang Q; College of Environment and Safe Engineering, Qingdao University of Science & Technology Qingdao 266042 China qiaochuliang@qust.edu.cn +86-15726078748.
  • Lan H; Chaofeng Steel Structure Group Co., Ltd, Xiaoshan Economic and Technological Development Zone No. 38, Beitang Road Hangzhou Zhejiang China.
RSC Adv ; 12(32): 20983-20990, 2022 Jul 14.
Article em En | MEDLINE | ID: mdl-35919155
ABSTRACT
In this study, the effect of pH shock during the treatment of sulfate-containing organic wastewater was investigated using an anaerobic fermentation system reinforced with graphene oxide (GO)/iron series systems. The results show that the anaerobic system with the GO/iron series systems exhibited enhanced resistance to pH shock. Among them, the GO/Fe0 system had the strongest resistance to pH shock, the systems of GO/Fe3O4 and GO/Fe2O3 followed close behind, while the blank system performed the worst. After pH shock, the CODCr removal rate, SO4 2- removal rate, and gas production of the GO/Fe0 group were significantly improved compared with those of the control group by 51.0%, 65.3%, and 34.6%, respectively, while the accumulation of propionic acid was the lowest. Further, detailed microbial characterization revealed that the introduction of the GO/iron series systems was beneficial to the formation of more stable anaerobic co-metabolic flora in the system, and the relative abundance of Geobacter, Clostridium, Desulfobulbus and Desulfovibrio increased after acidic and alkaline shock.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article