Your browser doesn't support javascript.
loading
Design of a microfluidic paper-based device for the quantification of phenolic compounds in wine samples.
Martínez-Pérez-Cejuela, H; Mesquita, Raquel B R; Couto, José A; Simó-Alfonso, E F; Herrero-Martínez, J M; Rangel, António O S S.
Afiliação
  • Martínez-Pérez-Cejuela H; Department of Analytical Chemistry, University of Valencia, Dr Moliner 50, 46100, Burjassot, Valencia, Spain.
  • Mesquita RBR; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal. Electronic address: rmesquita@ucp.pt.
  • Couto JA; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
  • Simó-Alfonso EF; Department of Analytical Chemistry, University of Valencia, Dr Moliner 50, 46100, Burjassot, Valencia, Spain.
  • Herrero-Martínez JM; Department of Analytical Chemistry, University of Valencia, Dr Moliner 50, 46100, Burjassot, Valencia, Spain.
  • Rangel AOSS; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
Talanta ; 250: 123747, 2022 Dec 01.
Article em En | MEDLINE | ID: mdl-35932718
In this work, the design and development of a microfluidic paper-based device (µPAD) for the quantification of total phenolic compounds (TPC) in wines is described. The developed µPAD was based upon the vertical flow concept and the colour reaction used was the known Folin-Ciocalteu reaction using gallic acid as reference phenolic compound. After studying operational parameters, namely type of paper, reagents and sample volume, a dynamic range of 5-50 mg L-1 was obtained with a limit of detection of 1.2 mg L-1. The described device proved to have good precision (relative standard deviation < 5%) and no significant interferences were observed from known compounds present in wines. Furthermore, the stability of the colour product and of the device itself were assessed; the µPAD was stable for 30 days (in the dark at room temperature) and it could be scanned up to 8 h after sample introduction. The developed µPAD pose as a simple method for TPC quantification and was successfully applied to several wine samples including sparkling and table wines with two different approaches: i) using gallic acid as reference compound with standard addition; and ii) using taniraisin with external calibration. The accuracy of the proposed µPAD method was assessed by comparison with the reference spectrophotometric method according to the International Organisation of Vine and Wine (OIV) recommendations.