Your browser doesn't support javascript.
loading
Dual mode assay of glutathione with Tb-doped g-C3N4/MnO2 nanoconjugates as fluorescence probe and Mn as elemental target.
Sun, Qi-Xuan; Zhang, Shang-Qing; Wei, Xing; Yang, Ting; Wang, Jian-Hua; Chen, Ming-Li.
Afiliação
  • Sun QX; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Zhang SQ; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Wei X; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Yang T; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Wang JH; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China. Electronic address: jianhuajrz@mail.neu.edu.cn.
  • Chen ML; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China. Electronic address: chenml@mail.neu.edu.cn.
Anal Chim Acta ; 1221: 340100, 2022 Aug 15.
Article em En | MEDLINE | ID: mdl-35934346
ABSTRACT
Glutathione (GSH) plays important roles in various physiological processes, thus highly sensitive assay of GSH and timely warning of its variation at trace level in complex biological matrixes is of great significance. However, this is challenging due to the coexisting reductive biomolecules and dynamic change of GSH levels in responding to various stimuli which remain largely unexploited. Herein, we report a dual mode protocol for the assay of GSH based on nanoconjugate g-C3N4Tb/MnO2 between MnO2 nanosheets and terbium-doped g-C3N4 (g-C3N4Tb) nanosheets. MnO2 moiety effectively quenches the emission at 546 nm from Tb3+ in the nanoconjugate, which is restored under the reduction of MnO2 by GSH to ensure fluorescence turn-on assay of GSH. Meanwhile, the generated Mn2+ facilitates inductively coupled plasma mass spectrometry (ICP-MS) detection to endow indirect highly sensitive assay of GSH. Fluorescence mode derived a limit of detection (LOD) of 0.17 µmol L-1 within a linear range of 0.5-160 µmol L-1, while ICP-MS resulted in a superior LOD of 0.016 µmol L-1 within 0.05-160 µmol L-1. Both detection modes provide excellent selectivity to GSH. The dual mode platform was validated by GSH assay in cell lysates. It was further demonstrated by monitoring the variation of dynamic change of GSH level under CuSO4 or cisplatin induced GSH consumption.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Manganês / Corantes Fluorescentes Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Manganês / Corantes Fluorescentes Idioma: En Ano de publicação: 2022 Tipo de documento: Article