Your browser doesn't support javascript.
loading
Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device.
Korsholm, Kasper; Kramer, Anders; Andersen, Asger; Saw, Jacqueline; Nørgaard, Bjarne Linde; Jensen, Jesper Møller; Nielsen-Kudsk, Jens Erik.
Afiliação
  • Korsholm K; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark.
  • Kramer A; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark.
  • Andersen A; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark.
  • Saw J; Department of Cardiology, Vancouver General Hospital, Vancouver, Canada.
  • Nørgaard BL; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark.
  • Jensen JM; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark.
  • Nielsen-Kudsk JE; Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus, Denmark. je.nielsen.kudsk@gmail.com.
J Interv Card Electrophysiol ; 66(2): 391-401, 2023 Mar.
Article em En | MEDLINE | ID: mdl-35951214
BACKGROUND: The left atrial appendage (LAA) sealing properties of the Amplatzer Amulet and Watchman FLX devices were compared using cardiac computed tomography (CT) follow-up. METHODS: Single-center cohort study of patients undergoing LAAO between 2017 and 2020. Two consecutive cohorts were enrolled, one treated with the Amplatzer Amulet (n = 150) up till 2019, and a second cohort treated with the Watchman FLX (n = 150) device from 2019. Cardiac CT was performed 2 months postprocedure. The primary outcome was complete LAA occlusion defined as no visible peri-device leak (PDL) and absence of contrast patency in the distal LAA. Secondary outcomes included PDL, contrast patency without visible PDL, PDL area, and periprocedural complications. RESULTS: Complete occlusion was achieved in 39 (30.5%) of the Amulet group, compared to 89 (71.8%) of the FLX group, p < 0.001. A PDL at the Amulet disc was present in 65 (50.8%), at the lobe in 16 (12.5%), and at both the disc and lobe in 13 (10.2%). For FLX, a PDL was present in 20 (16.1%). Contrast patency without visible PDL was observed in 24 (18.8%) and 15 (12.1%) of the Amulet and FLX group, respectively. The PDL area at the Amulet mid-lobe was 92 mm2 (59-158) and 32 mm2 (IQR 28-96) for FLX, p = 0.019. Device-related thrombosis occurred in 1 (0.7%) and 2 (1.3%), respectively (p = 0.99), with periprocedural adverse events occurring in 6 (4%) and 8 (5.3%) of the Amulet and FLX group (p = 0.79). CONCLUSION: Complete LAA occlusion was achieved in a significantly higher proportion treated with the Watchman FLX compared to the Amulet device. PDL was smaller with the FLX than the Amulet. Conceptual device design differences make interpretation of results complex, and additional studies with clinical outcomes are needed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Apêndice Atrial / Acidente Vascular Cerebral / Dispositivo para Oclusão Septal Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Apêndice Atrial / Acidente Vascular Cerebral / Dispositivo para Oclusão Septal Idioma: En Ano de publicação: 2023 Tipo de documento: Article