Your browser doesn't support javascript.
loading
Accurate Determination of the Degree of Deacetylation of Chitosan Using UPLC-MS/MS.
Xue, Ting; Wang, Wenqing; Yang, Zhiyuan; Wang, Fanjun; Yang, Lei; Li, Jian; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Dou, Guifang; Meng, Zhiyun.
Afiliação
  • Xue T; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Wang W; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Yang Z; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Wang F; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Yang L; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Li J; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Gan H; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Gu R; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Wu Z; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Dou G; Beijing Institute of Radiation Medicine, Beijing 100850, China.
  • Meng Z; Beijing Institute of Radiation Medicine, Beijing 100850, China.
Int J Mol Sci ; 23(15)2022 Aug 08.
Article em En | MEDLINE | ID: mdl-35955947
The mole fraction of deacetylated monomeric units in chitosan (CS) molecules is referred to as CS's degree of deacetylation (DD). In this study, 35 characteristic ions of CS were detected using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS). The relative response intensity of 35 characteristic ion pairs using a single charge in nine CS samples with varying DDs was analyzed using 30 analytical methods. There was a good linear relationship between the relative response intensity of the characteristic ion pairs determined using ultrahigh performance (UP) LC-MS/MS and the DD of CS. The UPLC-MS/MS method for determining the DD of CS was unaffected by the sample concentration. The detection instrument has a wide range of application parameters with different voltages, high temperatures, and gas flow conditions. This study established a detection method for the DD of CS with high sensitivity, fast analysis, accuracy, stability, and durability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quitosana / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quitosana / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2022 Tipo de documento: Article