Your browser doesn't support javascript.
loading
Comparison between Automatic and Semiautomatic System for the 3D Echocardiographic Multiparametric Evaluation of RV Function and Dimension.
Penso, Marco; Ranalletta, Remo Antonio; Pepi, Mauro; Garlaschè, Anna; Ali, Sarah Ghulam; Fusini, Laura; Mantegazza, Valentina; Muratori, Manuela; Maragna, Riccardo; Tamborini, Gloria.
Afiliação
  • Penso M; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Ranalletta RA; Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, 20133 Milan, Italy.
  • Pepi M; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Garlaschè A; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Ali SG; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Fusini L; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Mantegazza V; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Muratori M; Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, 20133 Milan, Italy.
  • Maragna R; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
  • Tamborini G; Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
J Clin Med ; 11(15)2022 Aug 03.
Article em En | MEDLINE | ID: mdl-35956143
ABSTRACT

BACKGROUND:

The right ventricle (RV) plays a pivotal role in cardiovascular diseases and 3-dimensional echocardiography (3DE) has gained acceptance for the evaluation of RV volumes and function. Recently, a new artificial intelligence (AI)-based automated 3DE software for RV evaluation has been proposed and validated against cardiac magnetic resonance. The aims of this study were three-fold (i) feasibility of the AI-based 3DE RV quantification, (ii) comparison with the semi-automatic 3DE method and (iii) assessment of 2-dimensional echocardiography (2DE) and strain measurements obtained automatically.

METHODS:

A total of 203 subject (122 normal and 81 patients) underwent a 2DE and both the semi-automatic and automatic 3DE methods for Doppler standard, RV volumes and ejection fraction (RVEF) measurements.

RESULTS:

The automatic 3DE method was highly feasible, faster than 2DE and semi-automatic 3DE and data obtained were comparable with traditional measurements. Both in normal subjects and patients, the RVEF was similar to the two 3DE methods and 2DE and strain measurements obtained by the automated system correlated very well with the standard 2DE and strain ones.

CONCLUSIONS:

results showed that rapid analysis and excellent reproducibility of AI-based 3DE RV analysis supported the routine adoption of this automated method in the daily clinical workflow.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article