Your browser doesn't support javascript.
loading
Microdosimetric investigation for multi-ion therapy by means of silicon on insulator (SOI) microdosimeter.
Sakata, Dousatsu; Lee, Sung Hyun; Tran, Linh T; Pan, Vladimir; Nakaji, Taku; Mizuno, Hideyuki; Kok, Angela; Povoli, Marco; Rosenfeld, Anatoly; Inaniwa, Taku.
Afiliação
  • Sakata D; Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, QST, 263-8555 Chiba, Japan.
  • Lee SH; Division of Health Science, Osaka University, 565-0871 Osaka, Japan.
  • Tran LT; Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, QST, 263-8555 Chiba, Japan.
  • Pan V; Department of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, 990-9585 Yamagata, Japan.
  • Nakaji T; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Mizuno H; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Kok A; Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, QST, 263-8555 Chiba, Japan.
  • Povoli M; Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, QST, 263-8555 Chiba, Japan.
  • Rosenfeld A; Department of Smart Sensors and Microsystems, SINTEF Digital, Gaustadalleen 23C, 0373 Oslo, Norway.
  • Inaniwa T; Department of Smart Sensors and Microsystems, SINTEF Digital, Gaustadalleen 23C, 0373 Oslo, Norway.
Phys Med Biol ; 67(21)2022 10 21.
Article em En | MEDLINE | ID: mdl-35961294
ABSTRACT
Objective.Ion radiotherapy with protons or carbon ions is one of the most advanced clinical methods for cancer treatment. To further improve the local tumor control, ion radiotherapy using multiple ion species has been investigated. Due to complexity of dose distributions delivered by multi-ion therapy in a tumor, a validation strategy for the planned treatment efficacy must be established that can be potentially used in the quality assurance (QA) protocol for the multi-ion treatment plans. In previous work, we demonstrated that the microdosimetric approach using the silicon on insulator (SOI) microdosimeter is practical for validating cell surviving fraction (SF) of MIA PaCa-2 cells in the independent fields of helium, carbon, oxygen, and neon ion beams.Approach.This paper extends the previous study, and we demonstrate a microdosimetry based approach as a pilot study to build the QA protocol in the multi-ion therapy predicting the cell SF along the spread-out Bragg peak obtained by combined irradiations of He+O and C+Ne ions. Across the study, the SOI microdosimeter system MicroPlus was used for measurement of the lineal energy in individual ion fields followed by deriving the lineal energy of combined ion fields delivered by a pencil beam scanning system at HIMAC.Main results.The predicted cell SF based on derived lineal energy and dose in the combined fields was in good agreement with the planned cell SF by our in-house treatment planning system.Significance.The presented results indicated the potential benefit of the SOI microdosimeter system MicroPlus as the QA system in the multi-ion radiotherapy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Silício Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Silício Idioma: En Ano de publicação: 2022 Tipo de documento: Article