Your browser doesn't support javascript.
loading
Comparative analysis of dermal collagen and lipids in cereblon ablated mice using a multimodal nonlinear optical system.
Park, Chang Woo; Jeon, Seungje; Kwon, Seong-Hoon; Jung, Jun-Hyung; Seol, Jung Eun; Park, Chul-Seung; Cho, Steve K; Ko, Do-Kyeong.
Afiliação
  • Park CW; Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju, South Korea.
  • Jeon S; School of Life Sciences, Gwangju Institute of Science and Technology, Gwangju, South Korea.
  • Kwon SH; Smart Marine Therapeutics Center, Cardiovascular and Metabolic Disease Center, Inje University, Busan, South Korea.
  • Jung JH; Pohang Accelerator Laboratory, Pohang, Gyeongbuk, South Korea.
  • Seol JE; School of Life Sciences, Gwangju Institute of Science and Technology, Gwangju, South Korea.
  • Park CS; Smart Marine Therapeutics Center, Cardiovascular and Metabolic Disease Center, Inje University, Busan, South Korea.
  • Cho SK; Department of Dermatology, Inje University Busan Paik Hospital, Inje University, Busan, South Korea.
  • Ko DK; School of Life Sciences, Gwangju Institute of Science and Technology, Gwangju, South Korea.
J Biophotonics ; 16(2): e202200139, 2023 02.
Article em En | MEDLINE | ID: mdl-36127858
ABSTRACT
By utilizing a multimodal nonlinear optical system that combines coherent anti-Stokes Raman scattering and second harmonic generation to investigate biological characteristics of dermal tissues ex vivo, we demonstrate the potential feasibility of using this optical approach as a powerful new investigative tool for future biomedical research. For this study, our optical system was utilized for the first time to analyze lipid and collagen profiles in cereblon knockout (KO) mouse skin, and we were able to discover significant alterations in the number of carbon-carbon double bonds (wild-type vs. cereblon KO; NCC 0.75 vs. 0.85) of skin fatty acids in triacylglycerides as well as changes in dermal collagen fibers (25% reduction in cereblon KO). By adopting our optical system to biological studies, we provide researchers with another diagnostic approach to validate their experimental results, which will significantly advance the state of biomedical research.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colágeno / Dispositivos Ópticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colágeno / Dispositivos Ópticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article