Your browser doesn't support javascript.
loading
Laser-Generated Guided Waves for Damage Detection in Metal-Lined Composite-Overwrapped Pressure Vessels.
Zhao, Jinling; Yang, Lehui; Wang, Hongyuan; Zhao, Jianping; Li, Nian; Chang, Le; Ji, Hongli; Qiu, Jinhao.
Afiliação
  • Zhao J; School of Mechanical and Power Engineering, Nanjing Tech University, Nanjing 211816, China.
  • Yang L; Jiangsu Key Lab of Design and Manufacture of Extreme Pressure Equipment, Nanjing Tech University, Nanjing 211816, China.
  • Wang H; School of Mechanical and Power Engineering, Nanjing Tech University, Nanjing 211816, China.
  • Zhao J; Jiangsu Key Lab of Design and Manufacture of Extreme Pressure Equipment, Nanjing Tech University, Nanjing 211816, China.
  • Li N; State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.
  • Chang L; School of Mechanical and Power Engineering, Nanjing Tech University, Nanjing 211816, China.
  • Ji H; Jiangsu Key Lab of Design and Manufacture of Extreme Pressure Equipment, Nanjing Tech University, Nanjing 211816, China.
  • Qiu J; School of Mechanical and Power Engineering, Nanjing Tech University, Nanjing 211816, China.
Polymers (Basel) ; 14(18)2022 Sep 13.
Article em En | MEDLINE | ID: mdl-36145965
ABSTRACT
This paper characterizes laser-generated guided waves in a metal-lined composite-overwrapped pressure vessel (COPV) to assess typical damage, including interfacial debonding and low-velocity impact damage. First, an eigenfrequency approach that avoids additional coding is utilized to theoretically analyze the dispersion characteristics of a COPV. The theoretical results show that interfacial debonding significantly alters dispersion curves, and the wavenumber of the L(0, 1) mode is sensitive to impact damage. Experimental verifications were conducted based on the full wavefield acquired using a scanning laser-ultrasonic system with a repetition rate of 1 kHz. By comparing the experimental dispersion curves with the theoretical ones, it was found that the metal-composite interface was not bonded. In addition, a local wavenumber estimation method was established to detect the impact damage by obtaining the spatial distribution of the wavenumber of the L(0, 1) mode.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article