Your browser doesn't support javascript.
loading
Modeling of Dynamic Recrystallization Evolution for Cr8 Alloy Steel and Its Application in FEM.
Chen, Xuewen; Liu, Bingqi; Zhang, Bo; Sun, Jiawei; Yang, Zhen; Zhou, Xudong; Huang, Tao; Yin, Danqing.
Afiliação
  • Chen X; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Liu B; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Zhang B; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Sun J; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Yang Z; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Zhou X; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Huang T; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
  • Yin D; School of Materials Science and Engineering, Henan University of Science and Technology, 263 Kaiyuan Avnue, Luyang 471023, China.
Materials (Basel) ; 15(19)2022 Oct 01.
Article em En | MEDLINE | ID: mdl-36234174
ABSTRACT
In the process of Cr8 roller production, the phenomenon of coarse grain size and uneven grain size often appears, which makes the mechanical properties of the material decrease sharply. Accurate dynamic recrystallization model is the basis for predicting the change of grain size during thermal processing, and is an important basis for refining grain and improving material properties. In this study, the isothermal compression experiment was carried out on Cr8 alloy steel at 900-1200 °C and 0.005-0.1 s-1 by Gleeble -1500D thermal simulation compressor, and the stress dates of Cr8 alloy steel were obtained. According to experimental data, the Kopp dynamic recrystallization model of Cr8 alloy steel was established. The dynamic recrystallization volume fraction obtained by Kopp model was compared with that obtained by experiment at the same temperature and strain rate. The correlation value was 0.988, and the root mean square error (RMSE) was 0.053, which proved that the DRX model established was reliable. Through the secondary development of the program, the DRX model of Cr8 alloy steel was written into the software Forge® to verify the microstructure evolution model. The compression process of a cylindrical specimen of Cr8 alloy steel at 0.1 s-1 and 1050 °C was simulated, and the DRX microstructure evolution of the alloy was calculated. The comparison between the final grain size calculation results and the test metallographic photos of samples in different deformation zones shows the relative error of the grain size was less than 10.6%, indicating that the DRX model of Cr8 alloy steel can better predict the dynamic recrystallization of Cr8 alloy steel.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article