Your browser doesn't support javascript.
loading
Influence of Aging on the Fracture Characteristics of Polyetheretherketone Dental Crowns: A Preliminary Study.
Lu, Wen-Ju; Srimaneepong, Viritpon; Chen, Chiang-Sang; Huang, Chang-Hung; Lin, Hui-Ching; Liu, Chia-Fei; Huang, Her-Hsiung.
Afiliação
  • Lu WJ; Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan.
  • Srimaneepong V; Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand.
  • Chen CS; Department of Orthopedic Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan.
  • Huang CH; Department of Materials and Textiles, Asia Eastern University of Science and Technology, New Taipei City 220, Taiwan.
  • Lin HC; Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan.
  • Liu CF; Department of Medical Research, MacKay Memorial Hospital, Taipei 251, Taiwan.
  • Huang HH; Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan.
Polymers (Basel) ; 14(19)2022 Oct 01.
Article em En | MEDLINE | ID: mdl-36236071
ABSTRACT
Although polyetheretherketone (PEEK) is becoming more widely used in dentistry applications, little is known about how aging will affect this material. Therefore, this study aimed to investigate the influence of an aging treatment on fracture characteristics of PEEK dental crowns. Additionally, the impact of the addition of titanium dioxide (TiO2) into PEEK was examined. Two types of commercial PEEK discs were used in this study, including TiO2-free and 20% TiO2-containing PEEK. The PEEK dental crowns were fabricated and aging-treated at 134 °C and 0.2 MPa for 5 h in accordance with the ISO 13356 specification before being cemented on artificial tooth abutments. The fracture loads of all crown samples were measured under compression tests. Results demonstrated that adding TiO2 enhanced the fracture load of PEEK crowns compared to TiO2-free PEEK crowns before the aging treatment. However, the aging treatment decreased the fracture load of TiO2-containing PEEK crowns while increasing the fracture load of TiO2-free PEEK crowns. The fracture morphology of TiO2-containing PEEK crowns revealed finer feather shapes than that of the TiO2-free PEEK crowns. We concluded that adding TiO2 increased the fracture load of PEEK crowns without aging treatment. Still, the aging treatment influenced the fracture load and microscopic fracture morphology of PEEK crowns, depending on the addition of TiO2.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article