Fabrication of a lattice structure with periodic open pores through three-dimensional printing for bone ingrowth.
Park, Jong Woong; Park, Hyenmin; Kim, June Hyuk; Kim, Hong Moule; Yoo, Chang Hyoung; Kang, Hyun Guy.
Afiliação
  • Park JW; Orthopaedic Oncology Clinic, Center for Rare Cancers, National Cancer Center, Goyang-si, Gyeonggi-do, Republic of Korea. jwpark82@ncc.re.kr.
  • Park H; Surgical Oncology branch, Division of Clinical Research, National Cancer Center, Goyang-si, Gyeonggi-do, Republic of Korea. jwpark82@ncc.re.kr.
  • Kim JH; Surgical Oncology branch, Division of Clinical Research, National Cancer Center, Goyang-si, Gyeonggi-do, Republic of Korea.
  • Kim HM; Orthopaedic Oncology Clinic, Center for Rare Cancers, National Cancer Center, Goyang-si, Gyeonggi-do, Republic of Korea.
  • Yoo CH; HANA AMT Company, Cheongju, Republic of Korea.
  • Kang HG; HANA AMT Company, Cheongju, Republic of Korea.
Sci Rep ; 12(1): 17223, 2022 10 14.
Article em En | MEDLINE | ID: mdl-36241776
ABSTRACT
Lattice structures for implants can be printed using metal three-dimensional (3D)-printing and used as a porous microstructures to enhance bone ingrowth as orthopedic implants. However, designs and 3D-printed products can vary. Thus, we aimed to investigate whether targeted pores can be consistently obtained despite printing errors. The cube-shaped specimen was printed with one side 15 mm long and a full lattice with a dode-thin structure of 1.15, 1.5, and 2.0 mm made using selective laser melting. Beam compensation was applied, increasing it until the vector was lost. For each specimen, the actual unit size and strut thickness were measured 50 times. Pore size was calculated from unit size and strut thickness, and porosity was determined from the specimen's weight. The actual average pore sizes for 1.15, 1.5, and 2.0 mm outputs were 257.9, 406.2, and 633.6 µm, and volume porosity was 62, 70, and 80%, respectively. No strut breakage or gross deformation was observed in any 3D-printed specimens, and the pores were uniformly fabricated with < 10% standard deviation. The actual micrometer-scaled printed structures were significantly different to the design, but this error was not random. Although the accuracy was low, precision was high for pore cells, so reproducibility was confirmed.