Your browser doesn't support javascript.
loading
Highly Sensitive Plasmonic Biosensors with Precise Phase Singularity Coupling on the Metastructures.
Youssef, Joelle; Zhu, Shaodi; Crunteanu, Aurelian; Orlianges, Jean-Christophe; Ho, Ho-Pui; Bachelot, Renaud; Zeng, Shuwen.
Afiliação
  • Youssef J; Light, Nanomaterials & Nanotechnologies (L2n), CNRS-ERL 7004, Université de Technologie de Troyes, 10000 Troyes, France.
  • Zhu S; Light, Nanomaterials & Nanotechnologies (L2n), CNRS-ERL 7004, Université de Technologie de Troyes, 10000 Troyes, France.
  • Crunteanu A; Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong 999077, China.
  • Orlianges JC; XLIM Research Institute, UMR 7252 CNRS/University of Limoges, 123 Avenue Albert Thomas, 87060 Limoges, France.
  • Ho HP; XLIM Research Institute, UMR 7252 CNRS/University of Limoges, 123 Avenue Albert Thomas, 87060 Limoges, France.
  • Bachelot R; Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong 999077, China.
  • Zeng S; Light, Nanomaterials & Nanotechnologies (L2n), CNRS-ERL 7004, Université de Technologie de Troyes, 10000 Troyes, France.
Biosensors (Basel) ; 12(10)2022 Oct 12.
Article em En | MEDLINE | ID: mdl-36291002
In this paper, we demonstrated the ability of a plasmonic metasensor to detect ultra-low refractive index changes (in the order of ∆n = 10-10 RIU), using an innovative phase-change material, vanadium dioxide (VO2), as the sensing layer. Different from current cumbersome plasmonic biosensing setups based on optical-phase-singularity measurement, our phase signal detection is based on the direct measurement of the phase-related lateral position shift (Goos-Hänchen) at the sensing interface. The high sensitivity (1.393 × 108 µm/RIU for ∆n = 10-10 RIU), based on the Goos-Hänchen lateral shift of the reflected wave, becomes significant when the sensor is excited at resonance, due to the near-zero reflectivity dip, which corresponds to the absolute dark point (lower than 10-6). GH shifts in the order of 2.997 × 103 µm were obtained using the optimal metasurface configuration. The surface plasmon resonance (SPR) curves (reflectivity, phase, GH) and electromagnetic simulations were derived using the MATLAB programming algorithm (by the transfer matrix method) and Comsol modeling (by finite element analysis), respectively. These results will provide a feasible way for the detection of cancer biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície Idioma: En Ano de publicação: 2022 Tipo de documento: Article