Your browser doesn't support javascript.
loading
[Effect of P311 microspheres-loaded thermosensitive chitosan hydrogel on the wound healing of full-thickness skin defects in rats].
Zhang, Q R; Chen, C Y; Xu, N; Lyu, D L; Jia, J Z; Li, W W; Luo, G X; Yu, Y L; Zhang, Yi.
Afiliação
  • Zhang QR; Department of Burns and Plastic Surgery, Affiliated Hospital of Nantong University, Nantong 226001, China.
  • Chen CY; State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Burn Research, the First Affiliated Hospital of Army Medical University (the Third Military Medical University), Chongqing Key Laboratory for Disease Proteomics, Chongqing 400038, China.
  • Xu N; State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Burn Research, the First Affiliated Hospital of Army Medical University (the Third Military Medical University), Chongqing Key Laboratory for Disease Proteomics, Chongqing 400038, China.
  • Lyu DL; Department of Burns and Plastic Surgery, the First Affiliated Hospital of Wannan Medical College, Wuhu 241001, China Beijing Jayyalife Biological Technology Company, Beijing 100094, China.
  • Jia JZ; State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Burn Research, the First Affiliated Hospital of Army Medical University (the Third Military Medical University), Chongqing Key Laboratory for Disease Proteomics, Chongqing 400038, China.
  • Li WW; Beijing Jayyalife Biological Technology Company, Beijing 100094, China.
  • Luo GX; State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Burn Research, the First Affiliated Hospital of Army Medical University (the Third Military Medical University), Chongqing Key Laboratory for Disease Proteomics, Chongqing 400038, China.
  • Yu YL; State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Burn Research, the First Affiliated Hospital of Army Medical University (the Third Military Medical University), Chongqing Key Laboratory for Disease Proteomics, Chongqing 400038, China.
  • Zhang Y; Department of Burns and Plastic Surgery, Affiliated Hospital of Nantong University, Nantong 226001, China.
Zhonghua Shao Shang Za Zhi ; 38(10): 914-922, 2022 Oct 20.
Article em Zh | MEDLINE | ID: mdl-36299202
Objective: To explore the effect of P311 microspheres-loaded thermosensitive chitosan hydrogel on the wound healing of full-thickness skin defects in rats. Methods: The method of experimental study was adopted. The polyvinyl alcohol/sodium alginate microspheres (simple microspheres), P311 microspheres, and bovine serum albumin labeled with fluorescein isothiocyanate (FITC-BSA) microspheres were prepared by water-in-oil emulsification, and then their morphology was observed under a light microscope/inverted fluorescence microscope. Chitosan solution was prepared, chitosan solution and ß-glycerol phosphate disodium hydrate were mixed to prepare simple thermosensitive hydrogels, and thermosensitive hydrogels loaded with simple microspheres or P311 microspheres were prepared by adding corresponding substances in simple thermosensitive hydrogels. The morphological changes of the prepared four liquids in the state of tilt was observed at 37 ℃. After being freeze-dried, the micromorphology of the prepared four liquids was observed under a scanning electron microscope. Eighteen 3-4-week-old male Sprague-Dawley rats were divided into normal group without any treatment, dressing group, chitosan group, hydrogel alone group, simple microspheres-loaded hydrogel group, and P311 microspheres-loaded hydrogel group, which were inflicted with one full-thickness skin defect wound on both sides of the back spine and were dealt correspondingly, with 3 rats in each group. Rats with full-thickness skin defects in the five groups were collected, the wound healing was observed on post injury day (PID) 0 (immediately), 5, 10, and 15, and the wound healing rates on PID 5, 10, and 15 were calculated. The wound and wound margin tissue of rats with full-thickness skin defects in the five groups on PID 15 and normal skin tissue in the same site of rats in normal group were collected, hematoxylin and eosin staining was conducted to observe the histological changes, immunohistochemical staining was performed to observe the expressions of CD31 and vascular endothelial growth factor (VEGF), and Western blotting was conducted to detect the protein expressions of CD31 and VEGF. The number of samples was all three. Data were statistically analyzed with one-way analysis of variance, analysis of variance for repeated measurement, and Bonferroni correction. Results: Simple microspheres were spherical, with loose and porous surface. The surfaces of P311 microspheres and FITC-BSA microspheres were smooth without pores, and the FITC-BSA microspheres emitted uniform green fluorescence. The diameters of the three microspheres were basically consistent, being 33.1 to 37.7 µm. Compared with chitosan solution and simple thermosensitive hydrogel, the structures of the two microspheres-loaded hydrogels were more stable in the state of tilt at 37 ℃. The two microspheres-loaded hydrogels had denser network structures than those of chitosan solution and simple thermosensitive hydrogel, and in the cross section of which microspheres with a diameter of about 30 µm could be seen. Within PID 15, the wounds of rats in the five groups were healed to different degrees, and the wound healing of rats in P311 microspheres-loaded hydrogel group was the best. On PID 5, 10, and 15, the wound healing rates of rats in dressing group and chitosan group were (26.6±2.4)%, (38.5±3.1)%, (50.9±1.5)%, (47.6±2.0)%, (58.5±3.6)%, and (66.7±4.1)%, respectively, which were significantly lower than (59.3±4.8)%, (87.6±3.2)%, (97.2±1.0)% in P311 microspheres-loaded hydrogel group (P<0.05 or P<0.01). The wound healing rates of rats in hydrogel alone group on PID 10 and 15, and in simple microspheres-loaded hydrogel group on PID 15 were (76.0±3.3)%, (84.5±3.6)%, and (88.0±2.6)%, respectively, which were significantly lower than those in P311 microspheres-loaded hydrogel group (P<0.05). The epidermis, hair follicles, and sebaceous glands could be seen in the normal skin of rats in normal group, without positive expressions of CD31 or VEGF. The wounds of rats in P311 microspheres-loaded hydrogel group on PID 15 were almost completely epithelialized, with more blood vessels, hair follicles, sebaceous glands, and positive expressions of CD31 and VEGF in the wounds than those of rats with full-thickness skin defects in the other four groups, and more protein expressions of CD31 and VEGF than those of rats in the other five groups. Conclusions: The P311 microspheres-loaded thermosensitive chitosan hydrogel can release the encapsulated drug slowly, prolong the drug action time, and promote wound healing in rats with full-thickness skin defects by promoting wound angiogenesis and re-epithelialization.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Anormalidades da Pele / Lesões dos Tecidos Moles / Quitosana Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Anormalidades da Pele / Lesões dos Tecidos Moles / Quitosana Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article