Using Magnetic Resonance Imaging During Childbirth to Demonstrate Fetal Head Moldability and Brain Compression: Prospective Cohort Study.
Ami, Olivier; Maran, Jean-Christophe; Musset, Dominique; Dubray, Claude; Mage, Gérard; Boyer, Louis.
Afiliação
  • Ami O; Clinique de la Muette - Ramsay Santé, Paris, France.
  • Maran JC; Image Guided Therapies, Institut Pascal, UMR 6602, Université Clermont Auvergne and CNRS, Paris, France.
  • Musset D; Image Guided Therapies, Institut Pascal, UMR 6602, Université Clermont Auvergne and CNRS, Paris, France.
  • Dubray C; Université Paris Sud 11, Paris, France.
  • Mage G; Centre d'investigations cliniques, Université Clermont Auvergne, Clermont Ferrand, France.
  • Boyer L; Service de gynécologie-obstétrique, Université Clermont Auvergne, Clermont Ferrand, France.
JMIR Form Res ; 6(11): e27421, 2022 Nov 30.
Article em En | MEDLINE | ID: mdl-36322921
ABSTRACT

BACKGROUND:

Childbirth is a physiological process with significant medical risk, given that neurological impairment due to the birthing process can occur at any time. Improvements in risk assessment and anticipatory interventions are constantly needed; however, the birthing process is difficult to assess using simple imaging technology because the maternal bony pelvis and fetal skeleton interfere with visualizing the soft tissues. Magnetic resonance imaging (MRI) is a noninvasive technique with no ionizing radiation that can monitor the biomechanics of the birthing process. However, the effective use of this modality requires teamwork and the implementation of the appropriate safeguards to achieve appropriate safety levels.

OBJECTIVE:

This study describes a clinically effective and safe method to perform real-time MRI during the birthing process. We reported the experience of our team as part of the IMAGINAITRE study protocol (France), which aimed to better understand the biomechanics of childbirth.

METHODS:

A total of 27 pregnant women were examined with 3D MRI sequences before going into labor using a 1-Tesla open-field MRI. Of these 27 patients, 7 (26%) subsequently had another set of 3D MRI sequences during the second stage of labor. Volumes of 2D images were transformed into finite element 3D reconstructions. Polygonal meshes for each part of the fetal body were used to study fetal head moldability and brain compression.

RESULTS:

All 7 observed babies showed a sugarloaf skull deformity and brain compression at the middle strait. The fetus showing the greatest degree of molding and brain shape deformation weighed 4525 g and was born spontaneously but also presented with a low Apgar score. In this case, observable brain shape deformation demonstrated that brain compression had occurred, and it was not necessarily well tolerated by the fetus. Depending on fetal head moldability, these observations suggest that cephalopelvic disproportion can result in either obstructed labor or major fetal head molding with brain compression.

CONCLUSIONS:

This study suggests the presence of skull moldability as a confounding factor explaining why MRI, even with the best precision to measure radiological landmarks, fails to accurately predict the modality of childbirth. This introduces the fetal head compliance criterion as a way to better understand cephalopelvic disproportion mechanisms in obstetrics. MRI might be the best imaging technology by which to explore all combined aspects of cephalopelvic disproportion and achieve a better understanding of the underlying mechanisms of fetal head molding and moldability.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article