Your browser doesn't support javascript.
loading
[Efficacy and safety of radiofrequency catheter ablation of septal hypertrophy guided by intracardiac echocardiography in hypertrophic obstructive cardiomyopathy].
Guo, X Y; Li, M M; Long, D Y; Sang, C H; Tang, R B; Jiang, C X; Du, X; Dong, J Z; Ma, C S.
Afiliação
  • Guo XY; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Li MM; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Long DY; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Sang CH; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Tang RB; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Jiang CX; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Du X; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Dong JZ; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
  • Ma CS; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029, China.
Zhonghua Yi Xue Za Zhi ; 102(44): 3549-3552, 2022 Nov 29.
Article em Zh | MEDLINE | ID: mdl-36418255
Nine patients identified as hypertrophic obstructive cardiomyopathy (HOCM) in Beijing Anzhen Hopspital who underwent ablation from March to July 2019 were included in the study. All patients had left ventricular outflow tract gradient (LVOTG) over 50 mmHg(1 mmHg=0.133 kPa)with significant symptoms despite not optimal drug therapy. Intracardiac echocardiography (ICE) was used to reconstruct septum and surrounding structures, and monitor the effect of ablation during procedure. Nine patients with HOCM were included,.of which 6 men and 3 women. The average age was (51.7±12.2) years. All patients underwent successful ablation after a mean of procedural time of (152.2±31.9) minutes and ablation time of (838.4±227.3) seconds. Except for one patients, all other patients had significant LVOTG reduction(P=0.001)within 50 mmHg after the procedure. Systolic anterior motion of the mitral valve disappeared in all patients after the procedure without major periprocedural complications. The LVOTG of these patients remained stable during follow-up. Radiofrequency ablation using ICE guidance is feasible in treating HOCM with promising efficacy and safety.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cardiomiopatia Hipertrófica / Ablação por Cateter Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cardiomiopatia Hipertrófica / Ablação por Cateter Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article