Your browser doesn't support javascript.
loading
Quantifying fluorescent nanoparticle uptake in mammalian cells using a plate reader.
Shin, Hye Ji; Kwak, Minjeong; Joo, Sihwa; Lee, Ji Youn.
Afiliação
  • Shin HJ; Biometrology Group, Division of Chemical and Biological Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-Ro, Yuseong-Gu, Daejeon, 34113, Republic of Korea.
  • Kwak M; Nanosafety Team, Safety Measurement Institute, Korea Research Institute of Standards and Science, 267 Gajeong-Ro, Yuseong-Gu, Daejeon, 34113, Republic of Korea.
  • Joo S; Bioimaging Team, Safety Measurement Institute, Korea Research Institute of Standards and Science, 267 Gajeong-Ro, Yuseong-Gu, Daejeon, 34113, Republic of Korea.
  • Lee JY; Biometrology Group, Division of Chemical and Biological Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-Ro, Yuseong-Gu, Daejeon, 34113, Republic of Korea. jylee@kriss.re.kr.
Sci Rep ; 12(1): 20146, 2022 11 23.
Article em En | MEDLINE | ID: mdl-36418509
ABSTRACT
In keeping with the rapid expansion of nanoparticle applications, various tools are required to investigate how nanoparticles interact with biological entities. Many assays have been developed to measure the cellular uptake of nanoparticles, but so far most of the methods are laborious and often non-quantitative. Here we developed an easily accessible and robust quantitative measurement method of the level of cellular uptake of fluorescently labeled nanoparticles using a plate reader. In the experimental design, potential issues that could lead to measurement variation were identified and addressed. For example, the variation in fluorescence intensity of samples due to differences in cell number was normalized to optical density, which is a physical value corresponding to the cell number. Number of washings and sample handling temperature were optimized to minimize the interference by residual nanoparticles and possible efflux of nanoparticles from cells, respectively. The developed assay was demonstrated with the lymphocyte cell line Jurkat to measure the cellular uptake of fluorescently labeled 50 nm polystyrene beads, and its applicability was further confirmed with the lung carcinoma cell line A549 and another lymphocyte cell line RPMI8226.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Corantes / Nanopartículas Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Corantes / Nanopartículas Idioma: En Ano de publicação: 2022 Tipo de documento: Article