Your browser doesn't support javascript.
loading
Spatial relationship of localized sources of persistent atrial fibrillation identified by a unipolar-based automated algorithm to complex fractionated atrial electrocardiograms and atrial low voltage areas.
Nagase, Takahiko; Kato, Ryuichi; Asano, So; Fukunaga, Hiroshi; Yoshida, Yoshinori; Hayashi, Yosuke; Sekiguchi, Yukio; Nanasato, Mamoru; Nitta, Junichi; Isobe, Mitsuaki.
Afiliação
  • Nagase T; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Kato R; Department of Cardiology, Higashiyamato Hospital, Tokyo, Japan.
  • Asano S; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Fukunaga H; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Yoshida Y; Department of Cardiology, Higashiyamato Hospital, Tokyo, Japan.
  • Hayashi Y; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Sekiguchi Y; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Nanasato M; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Nitta J; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Isobe M; Sakakibara Heart Institute, Tokyo, Japan.
J Cardiovasc Electrophysiol ; 34(2): 337-344, 2023 02.
Article em En | MEDLINE | ID: mdl-36423234
ABSTRACT

INTRODUCTION:

Spatial characteristics of localized sources of persistent atrial fibrillation (AF) identified by unipolar-based panoramic mapping software (CARTOFINDER) remain unclear. We evaluated spatial characteristics of bi-atrial AF localized sources in relation to complex fractionated atrial electrocardiograms (CFAEs) and atrial low voltage area (LVAs) (≤0.35 mV during AF). METHODS AND

RESULTS:

Twenty consecutive patients with persistent AF underwent bi-atrial voltage, CFAE, and CARTOFINDER mapping before the beginning of ablation (18 [90%] patients, initial procedure; 2 [10%] patients, repeat procedure). CFAEs were recorded using the interval confidence level (ICL) mode and defined as sites with a confidence level of ≥80% of maximal ICL number. We elucidated the following (1) differences in the rate of AF localized sources and CFAEs inside or outside the atrial LVAs; (2) distribution of AF localized sources and CFAEs; and (3) distance between the closest points of AF localized sources and CFAEs. A total of 270 AF localized sources and 486 CFAEs were identified in 20 patients. AF localized sources were confirmed more often outside atrial LVAs than CFAEs (71% vs. 46% outside LVA, p < .001). AF localized sources and CFAEs were diffusely distributed without any tendency in bi-atria. Mean distance between closest AF localized sources and CFAEs was 22 ± 8 mm.

CONCLUSION:

AF localized sources identified by CARTOFINDER are different therapeutic targets as compared to CFAEs and could be confirmed both inside and outside atrial LVAs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ablação por Cateter Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ablação por Cateter Idioma: En Ano de publicação: 2023 Tipo de documento: Article