Your browser doesn't support javascript.
loading
Value of 99m Tc-MIBI SPECT/CT in the localization of recurrent lesions in patients with suspected recurrent parathyroid carcinoma.
Guo, Yue-Hong; Huang, Jing-Wei; Wang, Ying; Lu, Ruigang; Yang, Min-Fu.
Afiliação
  • Guo YH; Department of Nuclear Medicine, Beijing Chaoyang Hospital, Capital Medical University.
  • Huang JW; Department of Nuclear Medicine, Beijing Chaoyang Hospital, Capital Medical University.
  • Wang Y; Department of the Pathology, Beijing Chaoyang Hospital, Capital Medical University.
  • Lu R; Department of Echocardiography, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
  • Yang MF; Department of Nuclear Medicine, Beijing Chaoyang Hospital, Capital Medical University.
Nucl Med Commun ; 44(1): 18-26, 2023 Jan 01.
Article em En | MEDLINE | ID: mdl-36437540
PURPOSE: Accurate preoperative localization of tumor-bearing lesions is crucial for the successful surgical management of suspected recurrent parathyroid carcinoma. The purpose of this study was to evaluate the diagnostic value of 99m-technetium-labeled methoxyisobutylisonitrile ( 99m Tc-MIBI) single-photon emission computed tomography/computed tomography (SPECT/CT) and cervical ultrasound, individually and in combination, for preoperative localization of recurrent/metastatic lesions. We also analyzed the value of 99m Tc-MIBI SPECT/CT in detecting ectopic lesions in patients with suspected recurrent parathyroid carcinoma. METHODS: Twenty-nine patients with suspected recurrent parathyroid carcinoma were included in this retrospective cohort study. Patients underwent preoperative 99m Tc-MIBI SPECT/CT and cervical ultrasound. The reference standard was postsurgical histopathology. The sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy of the two diagnostic modalities alone and in combination were analyzed. RESULTS: Of the 29 patients, histopathological results revealed 48 metastases/recurrent lesions in 26 patients. The diagnostic value of 99m Tc-MIBI SPECT/CT, cervical ultrasound, and the two modalities in combination were compared for the 27 patients who underwent new cervical surgery. Patient-level analysis of the combined use of 99m Tc-MIBI SPECT/CT and cervical ultrasound had the highest sensitivity (100.00%) and accuracy (96.30%). At the lesion level, 99m Tc-MIBI SPECT/CT had the highest specificity and PPV, at 100.00% respectively, whereas the combined use of 99m Tc-MIBI SPECT/CT and cervical ultrasound had the highest sensitivity, at 97.62%. Moreover, 99m Tc-MIBI SPECT/CT detected six ectopic lesions, and five of them showed increased 99m Tc-MIBI uptake. CONCLUSIONS: The combined use of 99m Tc-MIBI SPECT/CT and cervical ultrasound is the most efficient strategy in the diagnosis of parathyroid carcinoma relapse, whereas 99m Tc-MIBI SPECT/CT is the preferred method for localizing and analyzing cervical and extra-cervical lesions before the new surgery.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias das Paratireoides Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias das Paratireoides Idioma: En Ano de publicação: 2023 Tipo de documento: Article