Your browser doesn't support javascript.
loading
Cell viability and drug evaluation biosensing system based on disposable AuNPs/MWCNT nanocomposite modified screen-printed electrode for exocytosis dopamine detection.
Liu, Meng-Meng; Zhang, Feng-Feng; Liu, Hui; Wu, Mei-Juan; Liu, Zhou-Jie; Huang, Pin-Fang.
Afiliação
  • Liu MM; Department of Pharmacy, First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China.
  • Zhang FF; Department of Pharmacy, First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China.
  • Liu H; Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China.
  • Wu MJ; Department of Pharmacy, First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China.
  • Liu ZJ; Department of Pharmacy, First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China. Electronic address: liuzhoujie_08@163.com.
  • Huang PF; Department of Pharmacy, First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China. Electronic address: huangpf01@126.com.
Talanta ; 254: 124118, 2023 Mar 01.
Article em En | MEDLINE | ID: mdl-36470018
ABSTRACT
Cell viability, as an important index to evaluate drug effects, usually was measured by tetrazolium colorimetric assay, playing a key role in drug development and drug screening. Tedious operating procedures, unsatisfactory sensitivity and abominable environments perplex researchers to acquire more detailed in vivo-relevant biological information. Herein, a simple and low-cost cell viability and drug evaluation biosensing system-based on multiwalled carbon nanotubes, gold nanoparticles and Nafion modified screen-printed electrode (SPE) biosensor was constructed for detection of dopamine (DA) released from living cells to evaluate cytotoxicity of antineoplastic drugs such as cisplatin and resveratrol. The biosensing system was demonstrated to display exceptional selectivity, excellent flexibility and good stability toward DA measurement in complex bio-samples. Additionally, the satisfactory recoveries of DA in real samples revealed the reliability and accuracy of the biosensing system in practical application. The IC50 curves respectively obtained by the biosensing system and tetrazolium colorimetric assay provided similar IC50 value but distinctly different dose-effect relationship, which confirmed the enormous potential of the biosensor in cell viability and described drug efficacy profiles in cell function. In short, the cell viability and drug evaluation system using SPE biosensor paves a new way in drug screening and pharmaceutical application to measure bioactive molecule such as DA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono / Nanocompostos / Nanopartículas Metálicas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono / Nanocompostos / Nanopartículas Metálicas Idioma: En Ano de publicação: 2023 Tipo de documento: Article