Your browser doesn't support javascript.
loading
Characterization of relativistic electron-positron beams produced with laser-accelerated GeV electrons.
Song, Hoon; Kim, Chul Min; Won, Junho; Song, Jaehyun; Lee, Seongmin; Ryu, Chang-Mo; Bang, Woosuk; Nam, Chang Hee.
Afiliação
  • Song H; Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju, 61005, Korea.
  • Kim CM; Department of Physics and Photon Science, GIST, Gwangju, 61005, Korea.
  • Won J; Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju, 61005, Korea.
  • Song J; Advanced Photonics Research Institute, GIST, Gwangju, 61005, Korea.
  • Lee S; Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju, 61005, Korea.
  • Ryu CM; Department of Physics and Photon Science, GIST, Gwangju, 61005, Korea.
  • Bang W; Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju, 61005, Korea.
  • Nam CH; Department of Physics and Photon Science, GIST, Gwangju, 61005, Korea.
Sci Rep ; 13(1): 310, 2023 Jan 06.
Article em En | MEDLINE | ID: mdl-36609530
ABSTRACT
The characterization of an electron-positron beam generated from the interaction of a multi-GeV electron beam with a lead plate is performed using GEANT4 simulations. The dependence of the positron beam size on driver electron beam energy and lead converter thickness is investigated in detail. A pancake-like positron beam structure is generated with a monoenergetic multi-GeV driver electron beam, with the results indicating that a 5 GeV driver electron beam with 1 nC charge can generate a positron beam with a density of 1015-1016 cm-3 at one radiation length of lead. In addition, we find that electron-positron beams generated using above-GeV electron beams have neutralities greater than 0.3 at one radiation length of lead, whereas neutralities of 0.2 are observed when using a 200 MeV electron beam. The possibility of observing plasma instabilities in experiments is also examined by comparing the plasma skin depth with the electron-positron beam size. A quasi-neutral electron-positron plasma can be produced in the interaction between a 1 nC, 5 GeV electron beam and lead with a thickness of five radiation lengths. Our findings will aid in analyzing and interpreting laser-produced electron-positron plasma for laboratory astrophysics research.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article