Your browser doesn't support javascript.
loading
On-site Simultaneous Determination of Neonicotinoids, Carbamates, and Phenyl Pyrazole Insecticides in Vegetables by QuEChERS Extraction on Nitrogen and Sulfur co-doped Carbon Dots and Portable Mass Spectrometry.
Mou, Binglin; Zuo, Chengyi; Chen, La; Xie, Hongzhen; Zhang, Wentian; Wang, Qiqin; Wen, Luhong; Gan, Ning.
Afiliação
  • Mou B; Faculty of material science and chemical engineering, Ningbo University, Ningbo, 315211, China; College of food and pharmaceutical science, Ningbo University, Ningbo, 315211,China.
  • Zuo C; Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China.
  • Chen; The research institute of advanced technologies, Ningbo University, Ningbo, 315211,China; China Innovation Instrument Co., Ltd, Ningbo, 315000, China.
  • Xie H; Faculty of material science and chemical engineering, Ningbo University, Ningbo, 315211, China.
  • Zhang W; China Innovation Instrument Co., Ltd, Ningbo, 315000, China.
  • Wang Q; Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China.
  • Wen L; The research institute of advanced technologies, Ningbo University, Ningbo, 315211,China; China Innovation Instrument Co., Ltd, Ningbo, 315000, China; Guangzhou Hua Yue Hang Instrument Co., Ltd, Guangzhou, 510000, China. Electronic address: wenluhong@nbu.edu.cn.
  • Gan N; Faculty of material science and chemical engineering, Ningbo University, Ningbo, 315211, China. Electronic address: ganning@nbu.edu.cn.
J Chromatogr A ; 1689: 463744, 2023 Jan 25.
Article em En | MEDLINE | ID: mdl-36610187
ABSTRACT
In food safety monitoring, on-site and simultaneous detection of a variety of insecticides with different concentrations in the same matrix is necessary. However, the task remains challenging. In this study, a novel nitrogen and sulfur co-doped carbon dot (N, S-CD) was synthesized and used as a QuEChERS clean-up reagent to reduce matrix interferences in the determination of insecticides in vegetables. In addition, a portable mass spectrometer (µ-MS) was employed, without chromatography separation, to directly determine neonicotinoids, carbamates, and benzopyrazole insecticides (with acetamiprid, imidacloprid, thiamethoxam, fipronil, and carbofuran as models) in the pretreated samples. The N,S-CD µ-MS method exhibited effective clean-up performance with satisfactory matrix effects between -15.2% and 15.7%. The recoveries of spiked vegetable samples ranged from 82.2% to 109.7% for the five target insecticides, and the relative standard deviations (RSDs) ranged from 3.8% to 16.5%. The linear ranges were from 2.0 to 5.0 ng/g, with low detection limits (LOD) from 0.5 to 1.0 ng/g. Moreover, the total pretreatment and detection time was within 20 min. Thus, the incorporation of N,S-CD with QuEChERS extraction, together with the portable µ-MS system, could be a promising and feasible strategy for on-site, rapid, and simultaneous detection of various insecticides in vegetables.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Inseticidas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Inseticidas Idioma: En Ano de publicação: 2023 Tipo de documento: Article