Efficacy of a new fragmentation pattern in femtosecond laser-assisted cataract surgery with the Ziemer FEMTO LDV Z8.
Boden, Karl Thomas; Julich-Haertel, Henrike; Rickmann, Annekatrin; Szurman, Peter; Januschowski, Kai; Seitz, Berthold; Schlosser, Rosemarie; Wakili, Philip; Müller, Lisa Julia.
Afiliação
  • Boden KT; Eye Clinic Sulzbach, Knappschaft Hospital Saar GmbH, An der Klinik 10, 66280, Sulzbach, Germany. karl.boden@kksaar.de.
  • Julich-Haertel H; Klaus Heimann Eye Research Institute (KHERI), An der Klinik 10, 66280, Sulzbach, Germany. karl.boden@kksaar.de.
  • Rickmann A; Klaus Heimann Eye Research Institute (KHERI), An der Klinik 10, 66280, Sulzbach, Germany.
  • Szurman P; Eye Clinic Sulzbach, Knappschaft Hospital Saar GmbH, An der Klinik 10, 66280, Sulzbach, Germany.
  • Januschowski K; Centre for Ophthalmology, University Eye Hospital Tuebingen, Schleichstr. 12, 72076, Tübingen, Germany.
  • Seitz B; Klaus Heimann Eye Research Institute (KHERI), An der Klinik 10, 66280, Sulzbach, Germany.
  • Schlosser R; Eye Clinic Sulzbach, Knappschaft Hospital Saar GmbH, An der Klinik 10, 66280, Sulzbach, Germany.
  • Wakili P; Centre for Ophthalmology, University Eye Hospital Tuebingen, Schleichstr. 12, 72076, Tübingen, Germany.
  • Müller LJ; Klaus Heimann Eye Research Institute (KHERI), An der Klinik 10, 66280, Sulzbach, Germany.
Int Ophthalmol ; 43(7): 2237-2245, 2023 Jul.
Article em En | MEDLINE | ID: mdl-36781625
ABSTRACT

PURPOSE:

To determine the efficacy of different fragmentation patterns in femtosecond laser-assisted cataract surgery (FLACS) using Ziemer FEMTO LDV Z8.

METHODS:

We compared three different types of surgery conventional cataract surgery (CCS), FLACS with conventional radial slices (named No-Spiderweb), and FLACS with a novel fragmentation pattern (radial slices combined with one or two rings) called "Spiderweb." Visual acuity (VA), nuclear opacity (NO) according to the Lens Opacities Classification System (LOCS lll), effective phacoemulsification time (EPT) and vacuum time were obtained for 845 eyes.

RESULTS:

Using FLACS (Spiderweb + No-Spiderweb), EPT was significantly reduced by 26% compared to CCS (FLACS 2.46 ± 2.60 s; CCS 3.34 ± 2.89 s; ΔM = - 0.88 s, p < .001). Furthermore, EPT as a function of progression of lens opacity was found to be not only lower in Spiderweb compared to CCS, but also in comparison with No-Spiderweb. At NO3, a significant reduction of 65% in EPT was observed by using Spiderweb compared to CCS (Spiderweb 0.68 ± 1.23 s; CCS 1.96 ± 1.53 s; ΔM = - 1.28 s, p <.001). Interestingly, EPT at NO3 was also significantly reduced by 57% in Spiderweb compared to No-Spiderweb (Spiderweb 0.68 ± 1.23 s; No-Spiderweb 1.57 ± 1 .59 s; ΔM = - 0.90 s, p <.001). The use of Spiderweb only marginally extends the vacuum time compared to No-Spiderweb by 11 s (Spiderweb 209.13 ± 35.83 s; No-Spiderweb 198.35 ± 36.84 s; p = .003) and the postoperative improved VA showed no significant difference among the different types of surgery (all ps ≥ .05).

CONCLUSION:

FLACS significantly reduces EPT compared to CCS. Furthermore, the novel Spiderweb pattern significantly reduces EPT in patients with a cataract of NO3 compared to CCS, but also to FLACS with the existing radial pattern (No-Spiderweb).