Your browser doesn't support javascript.
loading
Agreement Between Dual-Energy X-ray Absorptiometry and Bioelectric Impedance Analysis for Assessing Body Composition in Athletes: A Systematic Review and Meta-Analysis.
Dzator, Stephen; Weerasekara, Ishanka; Shields, Melissa; Haslam, Rebecca; James, Daphne.
Afiliação
  • Dzator S; School of Health Sciences, College of Health, Medicine and Wellbeing, The University of Newcastle, Callaghan, Australia.
  • Weerasekara I; School of Health Sciences, College of Health, Medicine and Wellbeing, The University of Newcastle, Callaghan, Australia.
  • Shields M; Department of Health and Functioning, Faculty of Health and Social Sciences, Western Norway University of Applies Sciences, Bergen, Norway.
  • Haslam R; School of Allied Health Science and Practice, Faculty of Health and Medical Sciences, The University of Adelaide, SA, Australia.
  • James D; School of Health Sciences, College of Health, Medicine and Wellbeing, The University of Newcastle, Callaghan, Australia.
Clin J Sport Med ; 33(5): 557-568, 2023 09 01.
Article em En | MEDLINE | ID: mdl-36853902
ABSTRACT

OBJECTIVE:

To compare dual-energy x-ray absorptiometry (DXA) and bioelectric impedance analysis (BIA) in the assessment of body composition in athletes. DATA SOURCES A systematic review and meta-analysis was conducted collating peer-reviewed studies that compared BIA with DXA for the assessment of body composition in athletes that indexed in MEDLINE, CINAHL, EMBASE, and PsycINFO databases. MAIN

RESULTS:

After duplicate removal, 267 articles remained for full-text screening. Sixty-three studies remained for the final inclusion, with 8 focused on athletes (n = 461). Five studies were included in the meta-analysis and were rated as positive after risk of bias assessment, whereas the remaining were neutral. BIA overestimated fat-free mass (FFM) over DXA 2.78 (1.38-4.18) (mean difference ± 95% CI) with an effect size of 3.9( P < 0.001).

CONCLUSIONS:

BIA was found to overestimate total FFM when compared with DXA. Correlations are high between BIA and DXA; however, the limits of agreement are wide. Hence, BIA may not be a suitable substitute for DXA body composition scanning of athletes. Because of the low level of ionizing radiation exposure, the use of DXA should always be medically justified, and therefore, it is not recommended for repeat, longitudinal measurements in healthy subjects.We recommend that clinicians do not use BIA interchangeably with DXA in the assessment of body composition in athletes. Considerations should be made over the safety and appropriateness of DXA in young healthy adults. For long-term use, BIA can be warranted for athletes.PROSPERO Registration Number CRD42020183777.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Composição Corporal / Atletas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Composição Corporal / Atletas Idioma: En Ano de publicação: 2023 Tipo de documento: Article