Your browser doesn't support javascript.
loading
Accuracy of a 3-dimensionally printed custom endoscopy port for minimally invasive ventral slot decompression in dogs: A cadaveric study.
Kang, Jinsu; Lee, Seungeon; Heo, Suyoung; Kim, Namsoo.
Afiliação
  • Kang J; Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Iksan, Republic of Korea.
  • Lee S; Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Iksan, Republic of Korea.
  • Heo S; Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Iksan, Republic of Korea.
  • Kim N; Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Iksan, Republic of Korea.
Vet Surg ; 52(8): 1158-1170, 2023 Nov.
Article em En | MEDLINE | ID: mdl-36938921
ABSTRACT

OBJECTIVE:

To evaluate the accuracy of a 3-dimensionally (3D)-printed custom endoscopy port (3DEP) for minimally invasive cervical ventral slot decompression. STUDY

DESIGN:

Cadaveric study. ANIMALS Fifteen cadavers of dogs weighing between 3.1 and 34.4 kg.

METHODS:

Minimally invasive cervical ventral slots were created using a 3DEP and an endoscopic system at the C3-C4 intervertebral disc space in each dog by 1 experienced and 1 inexperienced surgeon. Postoperative computed tomography was performed to compare the planned and postoperative screw trajectories (angle, entry point, exit point, and length of the screw entering the spinal canal) and quantify slot formation dimensions.

RESULTS:

Thirty screws were inserted in 30 vertebral bodies. Mean screw angle deviation was less than 2.5°, entry and exit point deviation was less than 1.6 mm, and length of the screw entering the spinal canal was less than 0.6 mm. No differences were identified between the experienced and inexperienced surgeons. Ventral slot length ratio was 30.15 ± 1.86 for the experienced surgeon and 29.38 ± 1.61 for the inexperienced surgeon (p = .372). The mean ventral slot width ratio was 45.60 ± 1.80 for the experienced surgeon and 47.20 ± 1.54 for the inexperienced surgeon (p = .261).

CONCLUSION:

Screw positioning and creation of ventral slots were accurately performed using the 3DEP by both inexperienced and experienced surgeons. CLINICAL

SIGNIFICANCE:

The use of a 3DEP for minimally invasive cervical ventral slot decompression may be an alternative to the conventional ventral slot in dogs. Additional studies are needed to evaluate efficacy and safety.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças do Cão / Endoscopia Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças do Cão / Endoscopia Idioma: En Ano de publicação: 2023 Tipo de documento: Article