Your browser doesn't support javascript.
loading
Natural progression of the pubofemoral distance with age and its correlation with future acetabular index.
Chang, Wen-Chieh; Hsu, Kuei-Hsiang; Su, Yu-Ping.
Afiliação
  • Chang WC; Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
  • Hsu KH; Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Su YP; Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Eur Radiol ; 33(9): 6473-6481, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37012547
ABSTRACT

OBJECTIVES:

This study investigated the progression of pubofemoral distance (PFD) with age and assessed the correlation between PFD and late acetabular index (AI) measurements.

METHODS:

This prospective observational study was conducted between January 2017 and December 2021. We enrolled 223 newborns who underwent the first, second, and third hip ultrasounds, and pelvis radiograph at a mean age of 18.6 days, 3.1 months, 5.2 months, and 6.8 months, respectively. The difference between PFD measured at serial ultrasounds and the correlation with AI were analyzed.

RESULTS:

The PFD increased significantly (p < 0.001) at serial measurements. The mean PFD at the first, second, and third ultrasounds were 3.3 (2.0-5.7), 4.3 (2.9-7.2), and 5.1 (3.3-8.0) mm, respectively. The PFD at three ultrasounds were all significantly (p < 0.001) and positively correlated with AI, with the Pearson correlation coefficients being 0.658, 0.696, and 0.753 for the first, second, and third ultrasounds, respectively. Using AI as reference, the diagnostic ability of PFD was calculated by the areas under the receiver operating characteristic curve, which was 0.845, 0.902, and 0.938 for the first, second, and third PFD, respectively. For the first, second, and third ultrasounds, PFD cutoff values of ≥ 3.9, ≥ 5.0, and ≥ 5.7 mm, respectively, yielded the greatest sensitivity and specificity in predicting late abnormal AI.

CONCLUSION:

The PFD naturally progresses with age and is positively correlated with AI. The PFD has potential for predicting residual dysplasia. However, the cutoff for abnormal PFD values may require adjustment according to the patient's age. KEY POINTS • The pubofemoral distance measured in hip ultrasonography naturally increases as the infant's hips mature. • The early pubofemoral distance demonstrates a positive correlation with late acetabular index measurements. • The pubofemoral distance may help physicians predict abnormal acetabular index. However, the cutoff for abnormal pubofemoral distance values may require adjustment according to patient's age.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Luxação Congênita de Quadril Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Luxação Congênita de Quadril Idioma: En Ano de publicação: 2023 Tipo de documento: Article