Your browser doesn't support javascript.
loading
On the applicability of cosine-modulated pulses for high-resolution solid-state NMR of quadrupolar nuclei with spin > 3/2.
Sasaki, Akiko; Trébosc, Julien; Nagashima, Hiroki; Amoureux, Jean-Paul.
Afiliação
  • Sasaki A; Bruker Japan K.K, 3-9, Moriya-cho, Kanagawa-ku, Yokohama-shi, Kanagawa, 221-0022, Japan; Interdisciplinary Research Center for Catalytic Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8565, Japan.
  • Trébosc J; Univ. Lille, CNRS, INRAE, Centrale Lille, Univ. Artois, FR 2638 - IMEC - Institut Michel-Eugène Chevreul, F-59000, Lille, France.
  • Nagashima H; Interdisciplinary Research Center for Catalytic Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8565, Japan.
  • Amoureux JP; Bruker Biospin, 34 rue de l'industrie, F-67166, Wissembourg, France; Univ. Lille, CNRS, Centrale Lille, ENSCL, Univ. Artois, UMR 8181 - UCCS - Unit of Catalysis and Chemistry of Solids, F-59000, Lille, France. Electronic address: jean-paul.amoureux@univ-lille1.fr.
Solid State Nucl Magn Reson ; 125: 101863, 2023 Jun.
Article em En | MEDLINE | ID: mdl-37060799
ABSTRACT
In MQMAS-based high-resolution solid-state NMR experiments of half-integer spin quadrupolar nuclei, the high radiofrequency (RF) field requirement for the MQ excitation and conversion steps with two hard-pulses is often a sensitivity limiting factor in many practical applications. Recently, the use of two cosine-modulated (cos) low-power (lp) pulses, lasting one-rotor period each, was successfully introduced for efficient MQ excitation and conversion of spin-3/2 nuclei with a reduced RF amplitude. In this study, we extend our previous investigations of spin-3/2 nuclei to systems with higher spin values and discuss the applicability of coslp-MQ excitation and conversion in MQMAS and MQ-HETCOR experiments under slow and fast spinning conditions. For the numerical simulations and experiments we used a moderate magnetic field of 14.1 T. Two spin-5/2 nuclei (85Rb and 27Al) are mainly employed with a large variety of CQ values, but we show that the practical set up is also available for higher spin values, such as spin-9/2 with 93Nb in Cs4Nb11O30. We demonstrate for nuclei with spin value larger than 3/2 a preferential use of coslp-MQ acquisition for low-gamma nuclei and/or large CQ values with a much reduced RF-field with respect to that of hard-pulses used with conventional methods.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Campos Magnéticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Campos Magnéticos Idioma: En Ano de publicação: 2023 Tipo de documento: Article