Your browser doesn't support javascript.
loading
Particle and gas phase sampling of PCDD/Fs and dl-PCBs by activated carbon fiber and GC/MS analysis.
Cerasa, Marina; Guerriero, Ettore; Balducci, Catia; Bacaloni, Alessandro; Ciccioli, Piero; Mosca, Silvia.
Afiliação
  • Cerasa M; Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.
  • Guerriero E; Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.
  • Balducci C; Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.
  • Bacaloni A; Chemistry Department, Mathematics, Physics and Natural Sciences Faculty, Sapienza University Piazzale Aldo Moro, 5, 00185, Rome, Italy.
  • Ciccioli P; Italian National Research Council, Institute for Biological Systems, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.
  • Mosca S; Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy. silvia.mosca@iia.cnr.it.
Environ Sci Pollut Res Int ; 30(24): 65192-65203, 2023 May.
Article em En | MEDLINE | ID: mdl-37079234
ABSTRACT
Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and polychlorobiphenyls (PCBs) are semi-volatile compounds and can be partitioned in the atmosphere between the gas and particulate phase, due to their physicochemical properties. For this reason, the reference standard methods for air sampling include a quartz fiber filter (QFF) for the particulate and a polyurethane foam (PUF) cartridge for the vapor phase, and it is the classical and most popular sampling method in the air. Despite the presence of the two adsorbing media, this method cannot be used for the study of the gas-particulate distribution, but only for a total quantification. This study presents the results and the performance aim to validate an activated carbon fiber (ACF) filter for the sampling of PCDD/Fs and dioxin-like PCBs (dl-PCBs) using laboratory and field tests. The specificity, precision, and accuracy of the ACF in relation to the QFF + PUF were evaluated through the isotopic dilution technique, the recovery rates, and the standard deviations. Then the ACF performance was assessed on real samples, in a naturally contaminated area, through parallel sampling with the reference method (QFF + PUF). The QA/QC was defined according to the standard methods ISO 16000-13 and -14 and EPA TO4A and 9A. Data confirmed that ACF meets the requirements for the quantification of native POPs compounds in atmospheric and indoor samples. In addition, ACF provided accuracy and precision comparable to those offered by standard reference methods using QFF + PUF, but with significant savings in terms of time and costs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Idioma: En Ano de publicação: 2023 Tipo de documento: Article