Your browser doesn't support javascript.
loading
Theoretical and experimental studies on mechanochromic triphenylamine based fluorescent "ON-OFF-ON" sensor for sequential detection of Fe3+ and deferasirox.
Alzahrani, Abdullah Yahya Abdullah; Khan, Khanzadi Omama; Rafique, Sanwa; Irshad, Hasher; Khan, Asad Muhammad; Shahzad, Sohail Anjum.
Afiliação
  • Alzahrani AYA; Department of Chemistry, Faculty of Science and Arts, King Khalid University, Mohail, Assir, Saudi Arabia.
  • Khan KO; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
  • Rafique S; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
  • Irshad H; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
  • Khadija; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
  • Khan AM; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
  • Shahzad SA; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan. Electronic address: sashahzad@cuiatd.edu.pk.
Spectrochim Acta A Mol Biomol Spectrosc ; 297: 122745, 2023 Sep 05.
Article em En | MEDLINE | ID: mdl-37084683
ABSTRACT
A novel triphenylamine (TPA) based sensor TTU was rationally designed and synthesized that exhibited reversible mechanochromic and aggregation induced emission enhancement (AIEE) properties. The AIEE active sensor was employed for fluorometric detection of Fe3+ in aqueous medium, with distinguished selectivity. The sensor showed a highly selective quenching response towards Fe3+ that is ascribed to complex formation with paramagnetic Fe3+. Subsequently, TTU-Fe3+ complex acted as a fluorescence sensor for the detection of deferasirox (DFX). The subsequent addition of DFX to TTU-Fe3+ complex led to the recovery of fluorescence emission intensity of sensor TTU that was attributed to the displacement of Fe3+ by DFX and release of sensor TTU. The proposed sensing mechanisms for Fe3+ and DFX was confirmed through 1H NMR titration experiment and DFT calculations. Frontier molecular orbitals (FMO), density of states (DOS), natural bond orbital (NBO), non-covalent interaction (NCI) and electron density difference (EDD) analysis were performed using DFT calculations to support the experimental results. Moreover, sensor TTU displayed colorimetric detection of Fe3+. Further, the sensor was employed for the detection of Fe3+ and DFX in real water samples. Finally, logic gate was fabricated by using sequential detection strategy.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article