Your browser doesn't support javascript.
loading
Effect of low-to-moderate hyperoxia on lung injury in preclinical animal models: a systematic review and meta-analysis.
Minkove, Samuel; Dhamapurkar, Rhea; Cui, Xizhong; Li, Yan; Sun, Junfeng; Cooper, Diane; Eichacker, Peter Q; Torabi-Parizi, Parizad.
Afiliação
  • Minkove S; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Dhamapurkar R; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Cui X; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Li Y; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Sun J; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Cooper D; NIH Library, Clinical Center, National Institutes of Health, Bethesda, MD, 20892, USA.
  • Eichacker PQ; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA.
  • Torabi-Parizi P; Critical Care Medicine Department, National Institutes of Health, Building 10, Room 2C145, 9000 Rockville Pike, Bethesda, MD, 20892, USA. torabiparizip@cc.nih.gov.
Intensive Care Med Exp ; 11(1): 22, 2023 Apr 24.
Article em En | MEDLINE | ID: mdl-37088856
ABSTRACT

BACKGROUND:

Extensive animal investigation informed clinical practice regarding the harmful effects of high fractional inspired oxygen concentrations (FiO2s > 0.60). Since questions persist whether lower but still supraphysiologic FiO2 ≤ 0.60 and > 0.21 (FiO2 ≤ 0.60/ > 0.21) are also harmful with inflammatory lung injury in patients, we performed a systematic review examining this question in animal models.

METHODS:

Studies retrieved from systematic literature searches of three databases, that compared the effects of exposure to FiO2 ≤ 0.60/ > 0.21 vs. FiO2 = 0.21 for ≥ 24 h in adult in vivo animal models including an inflammatory challenge or not were analyzed. Survival, body weight and/or lung injury measures were included in meta-analysis if reported in ≥ 3 studies.

RESULTS:

More than 600 retrieved reports investigated only FiO2s > 0.60 and were not analyzed. Ten studies with an inflammatory challenge (6 infectious and 4 noninfectious) and 14 studies without, investigated FiO2s ≤ 0.60/ > 0.21 and were analyzed separately. In seven studies with an inflammatory challenge, compared to FiO2 = 0.21, FiO2 ≤ 0.60/ > 0.21 had consistent effects across animal types on the overall odds ratio of survival (95%CI) that was on the side of harm but not significant [0.68 (0.38,1.23), p = 0.21; I2 = 0%, p = 0.57]. However, oxygen exposure times were only 1d in 4 studies and 2-4d in another. In a trend approaching significance, FiO2 ≤ 0.60/ > 0.21 with an inflammatory challenge consistently increased the standardized mean difference (95%CI) (SMD) in lung weights [0.47 (- 0.07,1.00), p = 0.09; I2 = 0%, p = 0.50; n = 4 studies] but had inconsistent effects on lung lavage protein concentrations (n = 3), lung pathology scores (n = 4) and/or arterial oxygenation (n = 4) (I2 ≥ 43%, p ≤ 0.17). Studies without an inflammatory challenge had consistent effects on lung lavage protein concentration (n = 3) SMDs on the side of being increased that was not significant [0.43 (- 0.23,1.09), p = 0.20; I2 = 0%, p = 0.40] but had inconsistent effects on body and lung weights (n = 6 and 8 studies, respectively) (I2 ≥ 71%, p < 0.01). Quality of evidence for studies was weak.

INTERPRETATION:

Limited animal studies have investigated FiO2 ≤ 0.60/ > 0.21 with clinically relevant models and endpoints but suggest even these lower FiO2s may be injurious. Given the influence animal studies examining FiO2 > 0.60 have had on clinical practice, additional ones investigating FiO2 ≤ 0.60/ > 0.21 appear warranted, particularly in pneumonia models.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article