Your browser doesn't support javascript.
loading
Sensitive determination of bisphenols in environmental samples by magnetic porous carbon solid-phase extraction combined with capillary electrophoresis.
Yang, Xiupei; Zhang, Maosen; Yang, Jing; Huo, Feng; Li, Yingying; Chen, Lianfang.
Afiliação
  • Yang X; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, China. Electronic address: xiupeiyang@cwnu.edu.cn.
  • Zhang M; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, China.
  • Yang J; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, China.
  • Huo F; School of Chemistry and Chemical Engineering, Analytical Testing Center, Institute of Micro&Nano Intelligent Sensing, Neijiang Normal University, Neijiang, 641100, China.
  • Li Y; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, China.
  • Chen L; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, China. Electronic address: chenlf0610@163.com.
J Chromatogr A ; 1701: 464052, 2023 Jul 19.
Article em En | MEDLINE | ID: mdl-37187097
ABSTRACT
Bisphenol compounds exist widely in the environment and pose potential hazards to the environment and human health, which has aroused widespread concern. Therefore, there is an urgent need for an efficient and sensitive analytical method to enrich and determine trace bisphenols in environmental samples. In this work, magnetic porous carbon (MPC) was synthesized by one-step pyrolysis combined with a solvothermal method for magnetic solid-phase extraction of bisphenols. The structural properties of MPC were characterized by field emission scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, and saturation magnetization analysis. Its adsorption properties were evaluated by adsorption kinetics and adsorption isotherm studies. By optimizing the magnetic solid-phase extraction and capillary electrophoresis separation conditions, a capillary electrophoresis separation and detection method for four bisphenols was successfully constructed. The results showed that the detection limits of the proposed method for the four bisphenols were 0.71-1.65 ng/mL, the intra-day and inter-day precisions were 2.27-4.03% and 2.93-4.42%, respectively, and the recoveries were 87.68%-108.0%. In addition, the MPC could be easily recycled and utilized, and even if the magnetic solid-phase extraction was repeated 5 times, the extraction efficiency could still be kept above 75%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Extração em Fase Sólida Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Extração em Fase Sólida Idioma: En Ano de publicação: 2023 Tipo de documento: Article