Your browser doesn't support javascript.
loading
Investigation of periodic characteristics of perturbed flow over a slender body.
Zhao, Li; Wang, Yankui; Qi, Zhongyang.
Afiliação
  • Zhao L; Ministry-of-Education Key Laboratory of Fluid Mechanics & Aircraft and Propulsion Laboratory, Ningbo Institute of Technology, Beihang University, Beijing 100191, China.
  • Wang Y; Ministry-of-Education Key Laboratory of Fluid Mechanics & Aircraft and Propulsion Laboratory, Ningbo Institute of Technology, Beihang University, Beijing 100191, China.
  • Qi Z; Ministry-of-Education Key Laboratory of Fluid Mechanics & Aircraft and Propulsion Laboratory, Ningbo Institute of Technology, Beihang University, Beijing 100191, China.
Heliyon ; 9(5): e16194, 2023 May.
Article em En | MEDLINE | ID: mdl-37215871
ABSTRACT
The asymmetric flow over a slender body was particularly sensitive to the nose at a high angle of attack (AoA). Two patterns of separation occurred on the noses of the pointed-nosed slender body and blunt-nosed slender body as open- and close-type separation, respectively. The effects of the bluntness were investigated at high AoA (α = 50°) to clarify the evolution of the separated pattern from open-to close-type separation by the nose and by the periodic characteristics of perturbed flow. Wind tunnel experimental tests were conducted to investigate the periodic characteristics of asymmetric flow at a Reynolds number ReD = 1.54 × 105, based on incoming free-stream velocity (U∞) and the diameter (D) of the model. A particle was attached to the tip of the nose to induce the perturbed flow and attain a definite and predictable asymmetric flow in experimental tests. The pressure scanning and surface oil-flow visualization techniques were used to capture the pressure distributions and flow separations. The major findings were that axial flow increases with the increase of bluntness, resulting in open-type separation turning into close-type separation, and the perturbation moved from downstream to upstream of starting points of the separation line. The critical bluntness of separation pattern switching from open-type to close-type located between 1.5 and 3. Thus, the management of perturbation on asymmetric flow pattern switched from directly participating in separation to influencing separation through micro-flow. Therefore, the locations of perturbation and starting points of the separation line were closely related to asymmetric flow management by perturbation, then affecting the periodic characteristics of perturbed flow.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article