Your browser doesn't support javascript.
loading
A highly selective and sensitive sensor for promethazine based on molecularly imprinted interface coated Au/Sn bimetal nanoclusters functionalized acupuncture needle microelectrode.
Liu, Hongying; Zhang, Cairui; Wang, Chenwei; Fan, Kai; Zhang, Yuqing; Fang, Lu; Li, Lihua; Ren, Chaoxiang; Yin, Zheng-Zhi; Lü, Zhong.
Afiliação
  • Liu H; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Zhang C; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Wang C; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Fan K; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Zhang Y; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Fang L; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Li L; College of Automation, Hangzhou Dianzi University, Hangzhou, 310018, China.
  • Ren C; Affiliated Dongyang Hospital of Wenzhou Medical University, Dongyang, 322100, China.
  • Yin ZZ; College of Biological, Chemical Science and Engineering, Jiaxiing University, Jiaxing, 314001, China. Electronic address: yinzhengzhi@zjxu.edu.cn.
  • Lü Z; Affiliated Dongyang Hospital of Wenzhou Medical University, Dongyang, 322100, China. Electronic address: lz3399@wmu.edu.cn.
Anal Chim Acta ; 1269: 341395, 2023 Aug 15.
Article em En | MEDLINE | ID: mdl-37290856
ABSTRACT
Promethazine (PMZ) is an effective antihistamine that is used as a nerve tranquilizer to treat mental disorders. However, drug abuse causes harm to the human body and also pollutes the environment to a certain extent. Therefore, it is crucial to develop a highly selective and sensitive biosensor for PMZ determination. An acupuncture needle (AN) was used as an electrode in 2015, and further research on the electrode's essence in electrochemistry is needed. In this work, a sensor based on a surface imprinted film coordinated Au/Sn biometal was first fabricated on AN via electrochemistry. The obtained cavities showed complementary and suitable sites for "N atom" electron transfer through the phenyl ring structure in promethazine, which is rigorous for the configuration near the interface. Under the optimal conditions, MIP/Au/Sn/ANE exhibits a good linear relationship in the range of 0.5 µM-500 µM, and the detection limit (LOD) is 0.14 µM (S/N = 3). The sensor exhibits good repeatability, stability, and selectivity and can be successfully used to analyze and detect PMZ in human serum and environmental water. The findings are scientifically significant for AN electrochemistry and the sensors have potential for in vivo medicamentosus monitoring in the future.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Terapia por Acupuntura / Impressão Molecular Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Terapia por Acupuntura / Impressão Molecular Idioma: En Ano de publicação: 2023 Tipo de documento: Article