Your browser doesn't support javascript.
loading
Short-Term Clinical Results After ILM Removal and Inverted ILM Flap for Macular Hole Repair - A Single-Center Retrospective Experience.
Michalewicz, Emilia; Kuerten, David; Djalali-Talab, Yassin; Mazinani, Babac; Walter, Peter; Koutsonas, Antonis.
Afiliação
  • Michalewicz E; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
  • Kuerten D; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
  • Djalali-Talab Y; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
  • Mazinani B; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
  • Walter P; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
  • Koutsonas A; Department of Ophthalmology, RWTH Aachen University, Aachen, Germany.
Clin Ophthalmol ; 17: 1605-1618, 2023.
Article em En | MEDLINE | ID: mdl-37304330
ABSTRACT

Purpose:

To compare results after ILM peeling and ILM inverted flap technique utilized the repair of full thickness macular holes, irrespective of their size. Patients and

Methods:

Pre- and postoperative data of 109 patients who suffered from a full thickness macular hole were retrospectively analyzed. Forty-eight patients were treated with an inverted ILM flap technique, 61 patients were treated with ILM peeling. All patients received a gas tamponade. The primary endpoint was macular hole closure as demonstrated by OCT scanning. Secondary endpoints were best corrected visual acuity and clinical complication rates.

Results:

For small and medium-sized macular holes the closure rates in the ILM flap technique group were 100% and 94%, respectively. For ILM peeling, the closure rate was identical (95%). For large macular holes, the closure rate was 100% in the flap versus 50% in the ILM peeling group, but visual acuity improved in both groups (ILM flap p=0.001, ILM peeling p=0.002). In both treatment groups, larger holes were associated with a reduced final visual outcome. For medium-sized macular holes, visual acuity significantly improved only in the ILM peeling group. Both techniques were associated with minimal and comparable side effects.

Conclusion:

In our limited series, the inverted ILM flap technique for repair of macular holes demonstrated a high closure rate. For large MHs, we saw a trend towards a better closure rate in the flap technique compared to ILM peel only. However, final visual acuity showed no significant difference between the groups. Clinical results and complications appeared to be comparable in both groups.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article